New message codes in display
For improved diagnostic some extra
Code | Message | Cause | Action |
501 | Electronic problem | Communication | Main switch Off/On |
|
| problem between MMI cir- | Check that wire between MMI circuit board and |
|
| cuit board and Main circuit | Main circuit board is properly |
|
| board | connected. |
|
|
| Replace MMI circuit board |
|
|
| Replace Main circuit board |
502 | Electronic problem | MMI circuit board memory | Replace MMI circuit board |
|
| problem |
|
503 | Electronic problem | Keyboard problem | Check that wire between keyboard and MMI circuit |
|
|
| board is properly connected. |
|
|
| Replace keyboard |
|
|
| Replace MMI circuit board |
504 | Electronic problem | Display problem | Replace MMI circuit board |
505 | Electronic problem | Parameter problem | Replace MMI circuit board |