Return to Section TOC Return to Master TOC

F-61TROUBLESHOOTING AND REPAIRF-61

TYPICAL DC WELD OUTPUT VOLTAGE WAVEFORM

MACHINE LOADED – SELECTOR SWITCH AT MAXIMUM POSITION

CH1

Return to Section TOC Return to Master TOC

Return to Section TOC Return to Master TOC

Return to Section TOC Return to Master TOC

0 volts

20 volts

5 ms

MACHINE LOADED TO 250 AMPS AT 40 VDC

This is the typical DC output voltage generated from a properly operating machine. Note that each vertical division represents 20 volts and that each horizontal division represents 5 milliseconds in time. The machine was loaded with a resistance grid bank.

Note: Scope probes connected at machine output terminals.

SCOPE SETTINGS

Volts/Div

20V/Div.

Horizontal Sweep

5 ms/Div.

Coupling

DC

Trigger

Internal

CLASSIC® 300D & 300G

Page 183
Image 183
Lincoln Electric SVM194-A service manual 61TROUBLESHOOTING and REPAIRF-61, Typical DC Weld Output Voltage Waveform