Lincoln Electric SVM194-A service manual Replacement, Genernator Brush HOLDER/COIL Cables

Models: SVM194-A

1 232
Download 232 pages 49.12 Kb
Page 194
Image 194

Return to Section TOC Return to Master TOC

F-72

 

TROUBLESHOOTING AND REPAIR

F-72

 

ALTERNATOR STATOR REMOVAL AND REPLACEMENT (continued)

 

 

 

ALTERNATOR STATOR REMOVAL

 

 

 

AND REPLACEMENT (continued)

 

 

13.

Clear the leads in preparation for remov-

14. Lift the eight brushes from the commuta-

 

 

 

ing the stator/end bracket.

tor. Note the position of the brushes for

 

 

 

 

reassembly.

 

FIGURE F.10 - GENERATOR BRUSH HOLDER CABLE REMOVAL

Return to Section TOC Return to Master TOC

GENERNATOR

BRUSH HOLDER/COIL

CABLES (4)

Return to Section TOC Return to Master TOC

Return to Section TOC Return to Master TOC

15.With the 1/2" wrench, disconnect and clear the four heavy cables from the gen- erator brush holders to the coils in the generator frame. It is not necessary to remove the brush holder jumper cables. See Figure F.10. Label leads and posi- tions for re-assembly.