Return to Section TOC Return to Master TOC
Return to Section TOC Return to Master TOC
Return to Section TOC Return to Master TOC
Return to Section TOC Return to Master TOC
A1.4 | INSTALLATION |
| A1.4 | ||||||||||||
|
|
| CAUTION |
|
|
|
| ||||||||
|
|
|
|
|
| WARNING |
|
| D | O NOT MOUNT OVER COMBUSTIBLE SU | R- | ||||
Do not attempt to use this equipment until y | ou | FACES. |
|
|
|
|
| ||||||||
have thoroughly read the engine manufacturerʼs | Where there is a combustible surface directly under | ||||||||||||||
manual supplied with your welder. It includes | stationary or fixed electrical equipment, the surface | ||||||||||||||
important safety precautions, detailed engine | shall be covered with a steel plate at least .06”(1.6mm) | ||||||||||||||
starting, operating and maintenance instructions, | thick, which shall extend not more than 5.90”(150mm) | ||||||||||||||
and parts lists. |
|
| beyond the equipment on all sides. |
|
|
|
| ||||||||
|
|
|
|
|
| ELECTRIC SHOCK can kill. |
|
| |||||||
|
|
|
|
|
| • Do not touch electrically live parts or | Machine Grounding |
|
|
|
| ||||
|
|
|
|
|
| electrode with skin or wet clothing. | According to the United States National Electrical | ||||||||
|
|
|
|
|
| • Insulate yourself from | work and | ||||||||
|
|
|
|
|
| ground |
|
| Code, the frame of this portable generator is not | ||||||
|
|
|
|
|
| • Always wear dry insulating gloves. | required to be grounded and is permitted to serve as | ||||||||
the grounding means for cord connected equipment | |||||||||||||||
|
|
|
|
|
| ENGINE EXHAUST can kill. |
|
| |||||||
|
|
|
|
|
| • Use in open, well ventilated areas or | plugged into its receptacle. |
|
|
|
| ||||
|
|
|
|
|
| vent exhaust outside. |
|
| Some state, local, or other codes or unusual operating | ||||||
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
| circumstances may require the machine frame to be | ||||||
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
| MOVING PARTS can injure. |
|
| grounded. It is recommended that you determine the | |||||||
|
|
|
|
|
|
|
| extent to which such requirements may apply to your | |||||||
|
|
|
|
|
| • Do not operate with doors open or | particular situation and follow them explicitly. A | ||||||||
|
|
|
|
|
| guards off. |
|
| machine grounding stud marked with the symbol |
|
|
| is | ||
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
| • Stop engine before servicing. | provided on the welding generator frame foot. In | gen- | |||||||
|
|
|
|
|
| • Keep away from moving parts. | eral, if the machine is to be grounded, it should be con- | ||||||||
nected with a #8 or larger copper wire to a solid earth | |||||||||||||||
ground such as a metal water pipe going into the | |||||||||||||||
|
|
| front of this operatorʼs manual. |
|
| ground for at least ten feet and having no insulated | |||||||||
|
|
|
|
|
|
|
| joints, or to the metal framework of a building which | |||||||
Exhaust Spark Arrester |
|
| has been effectively grounded. The U.S. National | ||||||||||||
|
| Code lists a number of alternate means of grounding | |||||||||||||
Some federal, state or local laws may require that | electrical equipment. |
|
|
|
| ||||||||||
engines be equipped with exhaust spark arresters | Lift Bail |
|
|
|
|
| |||||||||
when they are operated in certain locations where |
|
|
|
|
| ||||||||||
unarrested sparks may present a fire hazard. The | A lift bail is provided for lifting with a hoist. |
|
|
|
| ||||||||||
standard muffler included with this welder does not |
|
|
|
| |||||||||||
qualify as a spark arrester. When required by local reg- |
|
| WARNING |
|
|
|
| ||||||||
ulations, a suitable spark arrester must be installed |
|
|
|
|
|
| |||||||||
and properly maintained. |
|
| FALLING EQUIPMENT can cause injury. |
|
|
|
| ||||||||
|
|
|
|
|
| CAUTION |
|
|
|
| • Lift only with equipment of | ||||
|
|
|
|
|
|
|
|
|
| adequate lifting capacity. |
|
|
|
| |
Use of an incorrect arrester may lead to engine damage |
|
| • Be sure machine is stable |
|
|
|
| ||||||||
|
| when lifting. |
|
|
|
| |||||||||
or performance loss. Contact the engine manufacturer for |
|
| • Do not lift this machine using | ||||||||||||
specific recommendations. |
|
|
|
| lift bale if it is equipped with a | ||||||||||
|
| heavy accessory such as trail- | |||||||||||||
Location / Ventilation |
|
|
|
| er or gas cylinder. |
|
|
|
| ||||||
Always operate the welder with the doors closed. | • Do not lift machine if lift bale is damaged. |
|
|
|
| ||||||||||
Leaving the doors open changes the designed air flow | • Do not operate machine while suspended from | ||||||||||||||
and may cause overheating. |
|
| lift bale. |
|
|
|
|
| |||||||
The welder should be located to provide an unrestrict- | |||||||||||||||
ed flow of clean, cool air. Also, locate the welder so |
|
|
|
|
|
|
| ||||||||
that engine exhaust fumes are properly vented to an |
|
|
|
|
|
|
| ||||||||
outside area. |
|
|
|
|
|
|
|
|
|