B5.2

OPERATION

 

 

 

B5.2

 

SAFETY PRECAUTIONS

 

 

 

 

 

 

CAUTION

 

 

 

 

 

 

 

 

WARNING

 

 

 

 

DO NOT MOUNT OVER COMBUSTIBLE SURFACES.

 

Do not attempt to use this equipment until y

ou

Where there is a combustible surface directly under

 

have thoroughly read the engine manufacturerʼs

stationary or fixed electrical equipment, the surface

 

manual supplied with your welder. It includes

shall be covered with a steel plate at least .06”(1.6mm)

 

important safety precautions, detailed engine

thick, which shall extend not more than 5.90”(150mm)

 

starting, operating and maintenance instructions,

beyond the equipment on all sides.

 

 

and parts lists.

 

 

 

 

------------------------------------------------------------------------

------------------------------------------------------------------------

The Classic® 300G uses the GM 3.0L industrial water-

 

 

 

 

 

 

 

ELECTRIC SHOCK can kill.

 

 

 

 

 

 

 

 

 

 

 

• Do not touch electrically live parts or

cooled gasoline engine.

 

 

 

 

 

 

 

 

 

electrode with skin or wet clothing.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RATED OUTPUT

 

DUTY CYCLE

 

 

 

 

 

 

 

 

• Insulate yourself from

work and

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ground

 

 

 

 

 

250A @ 30V

 

 

100%

 

 

 

 

 

 

 

 

• Always wear dry insulating gloves.

 

300A @ 32V

 

 

60%

 

------------------------------------------------------------------------

 

 

 

 

 

 

 

 

 

 

 

ENGINE EXHAUST can kill.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

vent exhaust outside.

 

 

 

 

DESIGN FEATURES

 

 

 

 

 

 

 

 

 

• Use in open, well ventilated areas or

Control Panel

 

 

 

 

 

 

 

 

 

 

 

----------------------------------------------------

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MOVING PARTS can injure.

 

 

 

 

Both the engine and the welder controls are located on

 

 

 

 

 

 

 

• Do not operate with doors open or

one recessed panel at the exciter end of the machine. The

 

 

 

 

 

 

 

guards off.

 

 

 

 

welder controls consist of a five step “Current Range

 

 

 

 

 

 

 

• Stop engine before servicing.

Selector” switch and a “Fine Current Adjustment” rheo-

 

 

 

 

 

 

 

• Keep away from moving parts.

stat. The welder is equipped with a “Start” button, an

------------------------------------------------------------------------

“Ignition” switch, an “Idler” control switch, and a “Glow

 

See additional warning information at the

Plug” button for easier cold weather starting.

 

 

 

 

 

front of this operatorʼs manual.

 

 

 

 

The control panel also contains an engine temperature

 

 

 

 

 

 

 

 

 

Operate the welder with the doors closed. Leaving the

gauge, a battery charging ammeter, an oil pressure

 

doors open changes the designed air flow and can cause

gauge, two three prong grounding type receptacles and

 

overheating.

 

 

 

 

four circuit breakers for auxiliary power.

 

 

GENERAL DESCRIPTION

 

 

 

 

operation.

 

 

 

 

 

The Classic® 300G is a heavy duty, engine driven, DC arc

All Copper Windings - For long life and dependable

 

Engine Idler Control - The Classic® 300G is equipped

 

welding power source, capable of providing constant cur-

with an electronic automatic engine idle control. It auto-

 

rent output for stick welding or DC TIG welding. This

matically increases and decreases engine speed

when

 

welder is wound with all copper coils, rated at 300

starting and stopping welding or using auxiliary

 

amps/32 Volts, and provides other Classic® features such

power. A built-in time delay permits changing electrodes

 

as improved door latches and stainless hinges. With the

before the engine slows to its low idle speed. The “Idler”

 

addition of the optional K623-1 Wire Feed Module™ the

control switch on the panel locks the idler in high idle posi-

 

Classic® 300G will provide constant voltage output for

tion when desired.

 

 

 

 

 

running the LN-7, LN-23P, or LN-25 wire feeders. The

Auxiliary Power - 3.0 kVA of nominal 115/230V, 60Hz,

 

optional K924-4 Remote Control Kit (field installed) pro-

 

vides a switch, or K924-5 Remote Control Kits provide a

AC. Output voltage is maintained within ± 10% at all

 

receptacle and a remote control rheostat for remote fine

loads up to rated capacity. (See

Optional Features in

 

current and open circuit voltage adjustment.

 

 

 

 

Section C for Power Plug Kit.)

 

 

 

The Classic® 300G has an electronic Engine Protection

Welder Enclosure

- The complete welder is rubber

 

system. In the event of sudden low oil pressure or high

mounted on a rugged steel “C” channel base.

 

 

coolant temperature, the engine immediately shuts down.

The output terminals are placed at the side of the

 

The Classic® 300G has a current range of 40-350 DC

machines so that they are protected by the door. The out-

 

amps with output ratings as follows:

 

 

 

 

put terminals are labeled (+) and (-).

 

 

These units are also capable of providing 3 kVA of

Cranking System - A 12 volt electric starter is standard.

 

115/230 volts of 60 cycle AC auxiliary power.

 

 

 

 

CLASSIC® 300D & 300G

Page 100