Aquatic Fitness System

2005 Owner’s Manual

Spa “Included” – Dual-Temp Only

Congratulations, AquaFit™Dual Temp Owners! You not only get the pleasures of aquatic exercise in the “pool side,” you also have a “dedicated spa” on the other side. Take the time to read these additional instructions carefully because they contain information specific to the spa portion of your Aquatic Fitness System. If you have any questions, please contact your local Authorized Dimension One Spas Dealer.

The spa side is completely “self-contained” from the pool side. This means that the water in the spa circulates through its own closed system – including pumps and jets. It contains a separate filtration system and the water chemistry must also be managed separately using the guidelines contained in the Water Care Guide Part No. 01513-192.

The following features are included on your spa:

Meets or exceeds the most stringent requirements of UL1563 Standard for Safety for Electrical Spas as evaluated and inspected by Edison Test Labs (ETL).

Completely self-contained with load sharing capabilities

100% foam insulated

Top access, easy to clean filter systems

Water level referencing weir skimmer

Proportional FastFlo™ Heater

A variety of interchangeable jets

Exclusive, custom hand-set ceramic tile adds a distinctive touch

Built-in, automatic freeze protection

Automatic high/low speed filtration cycles

Additional Features

Programmable Digital control with digital display

CrystalZone® Water Management System

Long life, dual speed HydraMax pump

Dynamic LED Lighting

75 sq. ft. (6.97 m2) of filtration

Heater and Circulation Pump Control

On all Dimension One Spas, when the water temperature is 1° F (0.55° C) below the set temperature the heater will turn on and remain on until the water temperature rises to 1° F (0.55° C) above the set temperature. To prevent the spa from overheating, the circulation pump turns off when the water temperature rises 2° F (1.1° C) above the set temperature. When the water temperature cools down to the set temperature, the circulation pump will turn on.

The circulation pump will run for short periods when the water temperature is 2° F (1.1° C) above set temperature to provide optimum operation.

Smart Heat

Smart Heat optimizes heat recovery using the amperage that you have available. Along with computerized load sharing, that automatically recognizes the number of jet pumps in use, compares it with the available power, Smart Heat recognizes the difference between the set temperature and the actual water temperature, and adjusts the heater to optimize the heater output.