Dimension One Spas 01513-192 Troubleshooting Guide, Heating System, Electrical System, Symptom

Models: 01513-192

1 48
Download 48 pages 43.85 Kb
Page 43
Image 43
Troubleshooting Guide

Aquatic Fitness System

2005 Owner’s Manual

Troubleshooting Guide

Heating System

 

 

 

 

 

 

 

 

 

 

 

 

 

Symptom

 

Problem

 

Corrective Action

 

 

 

Does not heat

 

1.

Temperature setting is too low

1.

Turn up the thermostat

 

 

 

 

 

2.

Dirty filter

2.

Clean filter

 

 

 

 

 

3.

Flow switch out of adjustment

3.

Call for service

 

 

 

 

 

 

 

 

 

 

Too hot

 

1.

Temperature setting is to high

1.

Turn down the thermostat

 

 

 

 

 

2.

High limit tripped

2.

Call for service

 

 

Flashing temperature of 34°F or

 

Possible temperature sensor failure

 

Call for service

 

 

134°F appears on the display

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Electrical System

 

 

 

 

 

 

 

 

 

 

Symptom

 

Problem

Corrective Action

 

Will not turn on – in any mode

 

No power

Check circuit breaker and/or GFCI

 

Turns on by itself

 

Normal automatic daily power

No action required

 

 

 

 

filtration, or anti-freeze cycle

 

 

 

 

Light is out

 

Burned out bulb

Replace bulb

 

 

Pump shuts down unexpectedly

 

1. Automatic 30-minute timer has

1.

Push JETS pad again to start

 

while in use

 

shut pump off

 

another 30-minute cycle

 

 

 

 

2. Motor over-heated and

2.

If pump(s) will not restart when

 

 

 

 

automatic protective device

 

JETS pad is pushed, call for

 

 

 

 

has shut down pump(s)

 

service

 

 

 

 

 

 

 

Make sure that the equipment

 

 

 

 

 

 

panel vent area is not blocked.

 

 

 

 

 

 

Vent blockage can cause

 

 

 

 

 

 

serious damage to your

 

 

 

 

 

 

equipment.

 

 

3 flashing LEDs appear on the

 

Possible sensor errors

1.

Check water level

 

Top Side Control

 

 

2.

Clean filter

 

 

 

 

 

If problem persists:

 

 

 

 

 

 

1.

Turn off power

 

 

 

 

 

 

2.

Restart the system

 

 

 

 

 

If problem persists:

 

 

 

 

 

 

Call for service

Water System

 

 

 

 

 

 

 

 

 

 

 

Symptom

 

 

Problem

Corrective Action

 

Pulsating jets

 

 

Water level too low

Fill with water to 1” to 2” (2 to 5

 

 

 

 

 

 

 

centimeters) above the bottom of

 

 

 

 

 

 

 

the tile line

 

No Jet Action, or action is poor

 

1.

HydroTherapy Jets closed

1.

Open Jets

 

 

 

 

2.

Diverter Valve turned

2.

Turn the Diverter Valve

 

 

 

 

 

 

 

 

clockwise or counter

 

 

 

 

 

 

 

 

clockwise

 

 

 

 

3.

Dirty Filter

3.

Clean Filter

 

 

 

 

4.

Air lock

4.

Loosen pump union to allow air

 

 

 

 

 

 

 

 

to escape

 

 

 

 

5.

Gate valve closed

5.

Open gate valve

 

The water is cloudy or has a smell

 

 

The water has a chemical

1.

Check TA/pH

 

 

 

 

 

imbalance.

2.

Test and adjust

 

 

 

 

 

 

 

3.

Change Water if necessary

39

Page 43
Image 43
Dimension One Spas 01513-192 Troubleshooting Guide, Heating System, Electrical System, Water System, Symptom, Problem