Dimension One Spas 01513-192 manual Erroneous Temperature on the Display, Aquatic Fitness System

Models: 01513-192

1 48
Download 48 pages 43.85 Kb
Page 32
Image 32
Erroneous Temperature on the Display

Aquatic Fitness System

2005 Owner’s Manual

Flashing LED on the Control Panel

DO NOT ENTER THE WATER if you see 3 flashing LEDs on the

Digital Display Control. The system has detected a problem.

If you have flashing lights, but the LED Digital Display Window shows the current water temperature, you have a water flow problem. You will need to check the water level and/or clean the filters.

Before checking the water level or cleaning the filter be sure to test the water temperature. Do not rely exclusively on the accuracy of the temperature reading in the LED Digital Display Window. Make sure the water temperature is safe before cleaning the filters.

The flashing lights should stop once the problem is fixed. If the problem persists, reset the power to the spa by resetting the GFCI breaker.

If the error is not resolved after resetting the spa, contact your local Authorized Dimension One Spas Dealer, or authorized service center.

Erroneous Temperature on the Display

DO NOT ENTER THE WATER if you see a temperature reading of 32° F (0° C) or 136° F (57.8° C) without first checking the actual water temperature with a separate thermometer. The system has detected a Temperature Probe Failure and the water may be too hot, or too cold, to safely use.

Contact your local Authorized Dimension One Spas Dealer, or authorized service center.