Check the Idle Switch for proper operation. See wiring diagram.
Perkins powered units: The idle solenoid linkage, if so equipped, may be bent or out of adjustment. Check that the linkage moves freely and that the plunger does not bind in any way.
Check that the solenoid can freely pull in and solidly seat against its internal stop.
The idle solenoid may have failed. Disconnect the solenoid leads and check the resistance of the solenoid coil. See machine schematic for correct solenoid coil resistance. Check the resistance from the solenoid leads to the solenoid body, resistance should be very high, 500,000 (500k) ohms minimum.
Perform the Engine RPM
Adjustment Test.
The 2-CR Reed relay may be faulty. The reed relay should be electrically open if no current is flowing in the weld circuit. If there is continuity through the reed relay when the machine is off, it is defective and should be replaced.
There may be voltage in the toroidal current sensor circuit. Unplug the current sensor from the PC board. See wiring diagram.

Return to Section TOC Return to Master TOC

Return to Section TOC Return to Master TOC

Return to Section TOC Return to Master TOC

 

F-17

TROUBLESHOOTING AND REPAIR

F-17

 

Observe Safety Guidelines detailed in the beginning of this manual.

 

 

 

 

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

 

 

 

 

 

 

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

The machine will not idle down

FUNCTION PROBLEMS

 

 

 

 

 

 

Make sure the idle switch is in

 

 

 

to low RPM when weld and

the “AUTO IDLE” position.

 

 

 

auxiliary loads are removed.

Make sure there is no external

 

 

 

The machine has normal weld

 

 

 

and auxiliary output. The engine

load on the weld terminals or

 

 

 

starts and shuts down normally.

the auxiliary power

 

 

 

receptacles. Disconnect the

 

 

 

 

 

weld cables and unplug

 

 

 

 

 

anything that may be

 

 

 

 

 

connected to the auxiliary

 

 

 

 

 

receptacles.

 

 

 

 

 

For machines equipped with

 

 

 

 

 

an idle solenoid, check for

 

 

 

 

 

mechanical restrictions in the

 

 

 

 

 

idler solenoid linkage.

 

 

Return to Section TOC Return to Master TOC

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed. Call 1-888-935-3877.

CLASSIC® 300D & 300G

Page 139
Image 139
Lincoln Electric SVM194-A service manual Machine will not idle down