F-41TROUBLESHOOTING AND REPAIRF-41

EXCITER ROTOR RESISTANCE AND GROUND TESTS PROCEDURE

(Exciter / Auxiliary Power Alternator)

WARNING

Service and repair should be performed only by Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty. For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed throughout this manual.

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical trou- bleshooting assistance before you proceed. Call 1-888-935-3877.

TEST DESCRIPTION

This test will determine if the exciter / auxiliary power alternator rotor winding is open, shorted, or grounded.

MATERIALS NEEDED

Miscellaneous hand tools

Ohmmeter (Analog type meter required for dynamic resistance test.)

Wiring diagram

Return to Section TOC Return to Master TOC

CLASSIC® 300D & 300G

Page 163
Image 163
Lincoln Electric SVM194-A 41TROUBLESHOOTING and REPAIRF-41, Exciter Rotor Resistance and Ground Tests Procedure