4-2. Overload Protection
21
3
4
1Control Box
2Power Circuit Breaker In Racks For 230/460 Volt XMT 304/EX 300 Models And 230/460 Volt XMT 456/ Invision 456 Models);
Location Of
Each Power circuit breaker or fuse block protects the welding power source connected to it from overload.
If a Power circuit breaker opens, the matching welding power source shuts down. Manually reset the Power circuit breaker.
3
4Fuses
If fuse(s) in fuse block opens, the matching welding power source shuts down. To check fuse block, place line disconnect switch in Off position and open hinged fuse hold- er on applicable fuse block to ac- cess fuses. Check fuses, and re- place if necessary.
4-3. Troubleshooting
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Trouble |
| Remedy | |
|
|
|
|
|
No weld output from any welding | Place line disconnect switch in On position (see Section | |||
power sources; units completely |
|
| ||
inoperative. |
|
| ||
|
|
|
|
|
|
|
| Check and replace line fuse(s), if necessary, or reset circuit breakers (see Section | |
|
|
|
|
|
|
|
| Check for proper input power connections to rack (see Section | |
|
|
|
|
|
No weld output from one welding pow- | For racks containing Power circuit breakers, place applicable Power circuit breaker in On position; for | |||
er source. | racks containing fuse blocks, check fuses in applicable fuse block (see Section | |||
|
|
|
|
|
|
|
| Check for proper input power connections to welding power source (see Section | |
|
|
|
|
|
|
|
| Check applicable welding power source according to its Owner’s Manual. | |
|
|
|
|
|