3-10. Electrical Service Guide For XMT 304 4-Racks
Input Voltage | 230 | 460 | 575 | |
|
|
|
| |
Max Recommended Standard Fuse Or Circuit Breaker Rating In | 200 | 110 | 90 | |
Amperes | ||||
|
|
| ||
|
|
|
| |
Min Input Conductor Size In AWG/Kcmil | 2 | 6 | 8 | |
|
|
|
| |
Max Recommended Input Conductor Length In Feet (Meters) | 210 (64) | 301 (92) | 300 (91) | |
|
|
|
| |
Min Grounding Conductor Size In AWG/Kcmil | 6 | 6 | 8 | |
|
|
|
| |
Reference: 1996 National Electrical Code (NEC). |
|
| ||
|
|
|
|
3-11. Electrical Service Guide For XMT 304/EX 300 6-Racks
Input Voltage | 230 | 460 | 575 | |
|
|
|
| |
Max Recommended Standard Fuse Or Circuit Breaker Rating In | 300 | 175 | 125 | |
Amperes | ||||
|
|
| ||
|
|
|
| |
Min Input Conductor Size In AWG/Kcmil | 1/0 | 2 | 4 | |
|
|
|
| |
Max Recommended Input Conductor Length In Feet (Meters) | 215 (66) | 451 (137) | 467 (142) | |
|
|
|
| |
Min Grounding Conductor Size In AWG/Kcmil | 4 | 6 | 6 | |
|
|
|
| |
Reference: 1996 National Electrical Code (NEC). |
|
| ||
|
|
|
|
Input Voltage* | 460 | 575 |
|
|
|
Max Recommended Standard Fuse Or Circuit Breaker Rating In Amperes | 200 | 175 |
|
|
|
Min Input Conductor Size In AWG/Kcmil | 2 | 2 |
|
|
|
Max Recommended Input Conductor Length In Feet (Meters) | 210 (64) | 451 (137) |
|
|
|
Min Grounding Conductor Size In AWG/Kcmil | 6 | 8 |
|
|
|
* Due to current demands, a rack containing XMT/Invisions 456 requiring 230/460 volt input power must be connected to 460 volt input power only.
Reference: 1996 National Electrical Code (NEC). |