Return to Section TOC Return to Master TOC

F-59

TROUBLESHOOTING AND REPAIR

F-59

 

NORMAL OPEN CIRCUIT VOLTAGE WAVEFORM (115VAC SUPPLY)

 

 

HIGH IDLE – NO LOAD – FINE CURRENT CONTROL RHEOSTAT AT MAXIMUM

 

 

 

 

 

16.6 ms

 

 

CH1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Return to Section TOC Return to Master TOC

Return to Section TOC Return to Master TOC

Return to Section TOC Return to Master TOC

50 volts

5 ms

This is the typical auxiliary output voltage generated from a properly operating machine. Note that each vertical division represents 50 volts and that each horizontal division rep- resents 5 milliseconds in time.

Note: Scope probes connected at machine 115VAC receptacle.

SCOPE SETTINGS

Volts/Div

50V/Div.

Horizontal Sweep

5 ms/Div.

Coupling

DC

Trigger

Internal

CLASSIC® 300D & 300G

0 volts

Page 181
Image 181
Lincoln Electric SVM194-A High Idle no Load Fine Current Control Rheostat AT Maximum, Scope Settings, 16.6 ms, CH1