F-60TROUBLESHOOTING AND REPAIRF-60

NORMAL OPEN CIRCUIT DC WELD VOLTAGE WAVEFORM

HIGH IDLE – NO LOAD – FINE CURRENT CONTROL RHEOSTAT AND SELECTOR

SWITCH AT MAXIMUM

 

CH1

 

0 volts

50 volts

5 ms

Return to Section TOC Return to Master TOC

Return to Section TOC Return to Master TOC

This is the typical DC output voltage generated from a properly operating machine. Note that each vertical divi- sion represents 50 volts and that each horizontal division represents 5 milliseconds in time.

Note: Scope probes connected at machine output terminals.

SCOPE SETTINGS

Volts/Div

50V/Div.

Horizontal Sweep

5 ms/Div.

Coupling

DC

Trigger

Internal