Rev.0210

Electrical and Refrigeration Specifications

 

 

TEMPERATURE

 

DISCHG.

 

 

 

 

 

FAN SIZE

 

DEFROST

ELECTRICAL CIRCUITS

SELF CONTAINED UNIT DATA

 

 

 

 

 

BTU

 

 

AVG

 

 

AIR

 

T-STAT/

 

TYPE

&

 

FREQ.

115 V.

 

SELF CONTAINED

 

 

 

 

 

 

 

 

 

REQ’D

EVAP

PROD

DISC

 

VELOC

 

CUT IN

 

OF

 

NUMBER

&

E E FANS

STD.

LOW PRESSURE

 

 

 

 

 

 

 

 

LENGTH

PER FT.

TMP

 

TMP

TMP

 

@FPM

 

SETTINGS

 

COIL

 

OF MOTORS

 

DURATION

(OPT.)

 

 

FANS

CONTROL & SETTINGS

 

H.P.

 

VOLTS

 

AMPACITY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DBRP-01

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Crown

750

18°

 

41°

36°

 

50 to

 

Opt.

 

Forced

 

8" x 10°

 

50 min.

1.98

 

 

3.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100

 

 

 

Air

 

(6)

 

(2)

 

 

 

 

 

 

 

 

 

 

 

 

 

1 point

No

loads

 

- Connection

 

point

 

only

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 point

750

18°

 

41°

36°

 

50 to

 

Opt.

 

Forced

 

8" x 10°

 

50 min.

1.98

 

 

3.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100

 

 

 

Air

 

(6)

 

(3)

 

 

 

 

 

 

 

 

 

 

 

 

 

3 point

750

18°

 

41°

36°

 

50 to

 

Opt.

 

Forced

 

8" x 10°

 

50 min.

2.31

 

 

4.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100

 

 

 

Air

 

(7)

 

(3)

 

 

 

 

 

 

 

 

 

 

 

 

 

8'

750

18°

 

41°

36°

 

50 to

 

Opt.

 

Forced

 

8" x 10°

 

50 min.

.66

 

 

1.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100

 

 

 

Air

 

(2)

 

(2)

 

 

 

 

 

 

 

 

 

 

 

 

 

10'

750

18°

 

41°

36°

 

50 to

 

Opt.

 

Forced

 

8" x 10°

 

50 min.

.99

 

 

1.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100

 

 

 

Air

 

(3)

 

(2)

 

 

 

 

 

 

 

 

 

 

 

 

 

12'

750

18°

 

41°

36°

 

50 to

 

Opt.

 

Forced

 

8" x 10°

 

50 min.

1.32

 

 

2.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100

 

 

 

Air

 

(4)

 

(2)

 

 

 

 

 

 

 

 

 

 

 

 

 

14'

750

18°

 

41°

36°

 

50 to

 

Opt.

 

Forced

 

8" x 10°

 

50 min.

1.65

 

 

3.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100

 

 

 

Air

 

(5)

 

(2)

 

 

 

 

 

 

 

 

 

 

 

 

 

DBRP-01

Octagon

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Crown

750

18°

 

41°

36°

 

50 to

 

Opt.

 

Forced

 

8" x 10°

 

50 min.

2.64

 

 

4.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100

 

 

 

Air

 

(8)

 

(2)

 

 

 

 

 

 

 

 

 

 

 

 

 

DBRP-03

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8'

750

18°

 

41°

36°

 

50 to

 

Opt.

 

Forced

 

8" x 10°

 

50 min.

.66

 

 

1.2

30# Out

 

1

 

208/

 

13.0

 

 

 

 

 

 

 

 

 

100

 

 

 

Air

 

(2)

 

(3)

 

 

 

 

50# In

 

 

 

230

 

 

 

 

10'

750

18°

 

41°

36°

 

50 to

 

Opt.

 

Forced

 

8" x 10°

 

50 min.

.99

 

 

1.8

30# Out

 

1

 

208/

 

13.0

 

 

 

 

 

 

 

 

 

100

 

 

 

Air

 

(3)

 

(3)

 

 

 

 

50# In

 

 

 

230

 

 

 

 

12'

750

18°

 

41°

36°

 

50 to

 

Opt.

 

Forced

 

8" x 10°

 

50 min.

1.32

 

 

2.4

30# Out

 

11/2

 

208/

 

19.0

 

 

 

 

 

 

 

 

 

100

 

 

 

Air

 

(4)

 

(3)

 

 

 

 

50# In

 

 

 

230

 

-

 

 

14'

750

18°

 

41°

36°

 

50 to

 

Opt.

 

Forced

 

8" x 10°

 

50 min.

1.65

 

 

3.0

30# Out

 

11/2

 

208/

 

19.0

 

 

 

 

 

 

 

 

 

100

 

 

 

Air

 

(5)

 

(3)

 

 

 

 

50# In

 

 

 

230

 

-

 

 

16'

750

18°

 

41°

36°

 

50 to

 

Opt.

 

Forced

 

8" x 10°

 

50 min.

1.98

 

 

3.6

30# Out

 

2

 

208/

 

21.4

 

 

 

 

 

 

 

 

 

100

 

 

 

Air

 

(6)

 

(3)

 

 

 

 

50# In

 

 

 

230

 

-

 

 

18'

750

18°

 

41°

36°

 

50 to

 

Opt.

 

Forced

 

8" x 10°

 

50 min.

2.31

 

 

4.2

30# Out

 

2

 

208/

 

21.4

 

 

 

 

 

 

 

 

 

100

 

 

 

Air

 

(7)

 

(3)

 

 

 

 

50# In

 

 

 

230

 

-

 

 

20'

750

18°

 

41°

36°

 

50 to

 

Opt.

 

Forced

 

8" x 10°

 

50 min.

2.64

 

 

4.8

30# Out

 

3

 

208/

 

35.7

 

 

 

 

 

 

 

 

 

100

 

 

 

Air

 

(8)

 

(3)

 

 

 

 

50# In

 

 

 

230

 

 

 

 

22'

750

18°

 

41°

36°

 

50 to

 

Opt.

 

Forced

 

8" x 10°

 

50 min.

2.97

 

 

5.4

30# Out

 

3

 

208/

 

35.7

 

 

 

 

 

 

 

 

 

100

 

 

 

Air

 

(9)

 

(3)

 

 

 

 

50# In

 

 

 

230

 

 

 

 

24'

750

18°

 

41°

36°

 

50 to

 

Opt.

 

Forced

 

8" x 10°

 

50 min.

3.3

 

 

6.0

30# Out

 

3

 

208/

 

35.7

 

 

 

 

 

 

 

 

100

 

 

 

Air

(10)

(3)

 

 

 

 

50# In

 

 

230

 

 

 

 

26'

750

18°

 

41°

36°

 

50 to

 

Opt.

 

Forced

 

8" x 10°

 

50 min.

3.63

 

 

6.6

30# Out

3

208/

35.7

 

 

 

 

 

 

 

 

100

 

 

 

Air

(11)

(3)

 

 

 

 

50# In

 

 

230

 

 

 

 

28'

750

18°

 

41°

36°

 

50 to

 

Opt.

 

Forced

 

8" x 10°

 

50 min.

3.96

 

 

7.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100

 

 

 

Air

(12)

(3)

 

 

 

 

 

 

 

 

 

 

 

 

 

30'

750

18°

 

41°

36°

 

50 to

 

Opt.

 

Forced

 

8" x 10°

 

50 min.

4.29

 

 

7.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100

 

 

 

Air

(13)

(3)

 

 

 

 

 

 

 

 

 

 

 

 

 

32'

750

18°

 

41°

36°

 

50 to

 

Opt.

 

Forced

 

8" x 10°

 

50 min.

5.94

 

 

10.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100

 

 

 

Air

(14)

(3)

 

 

 

 

 

 

 

 

 

 

 

 

 

•Hussmann Chino reserves the right to change or revise case specifications and design11 in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions, or replacement of equipment previously sold or shipped. These changes may also affect the loads applicable to a particular case,

therefore always check the serial plate at the back of the case and/or consult the factory for the current loads for your particular equipment.

Page 11
Image 11
hussman 3, DBP, DBRP 01 manual DBRP-01, Electrical and Refrigeration Specifications