IGSV-ASCS-0303

Electrical

WIRING COLOR CODE

GREEN

GROUND

PURPLE

ANTI-SWEAT

ORANGE

LIGHTS

YELLOW

RECEPTACLE

RED / BLACK

T-STAT /SOLENOID230V

BLACK / WHITE

T-STAT / SOLENOID 115V

BROWN

FAN MOTORS

 

 

CASE MUST BE GROUNDED

NOTE: Refer to label affixed to case to determine the actual configuration as checked in the “TYPE INSTALLED” boxes.

ELECTRICAL CIRCUIT IDENTIFICATION

Standard lighting for all models will be full length fluorescent lamps located within the case at the top.

The switch controlling the lights, the plug provided for digital scale,and the thermometer are located at the rear of the case mullion.

The receptacle that is provided on the exterior back of these models is intended for computerized scales with a five amp maximum load, not for large motors or other high wattage appliances. It should be wired to a dedicated circuit.

CASE-TO CASE CONNECTORS

HUSSMANN/CHINO now provides “CASE-TO-CASE” locking electrical connector fittings on theASCS service cases. These connectors greatly simplify field installation thereby saving time and electrical installation costs.

NOTE: The total case electrical draw must not exceed 30 Amps ampacity at 115V in one connected lineup.

ELECTRICAL SERVICE RECEPTACLES (WHEN APPLICABLE)

The receptacles located on the exterior of the merchandiser are intended for scales and lighted displays. They are not intended nor suitable for large motors or other external appliances.

BEFORE SERVICING

Always Disconnect Electrical Power at the Main Disconnect when servicing or replacing any electrical component.

This includes (but not limited to) Fans, Heaters,

Thermostats, and Lights.

FIELD WIRING AND SERIAL PLATE AMPERAGE

Field wiring must be sized for component amperes printed on the serial plate.Actual ampere draw may be less than specified. Field wiring from the refrigeration control panel to the merchandisers is required for refrigeration thermostats. Most component amperes are listed in the “Case Specs” section, but always check the serial plate.

BALLAST LOCATION

Ballasts are located within the access panel that runs the length of the rear of the case. Refer to diagram on page 6.

WIRING AND SERIAL PLATE AMPERAGE

Field wiring must be sized for component amperes stamped on the serial plate. Actual ampere draw may be less than specified. Field wiring from the refrigeration control panel to the merchandisers is required for refrigeration thermostats. Most component amperes are listed in the "Case Specs" section, but always check the serial plate.

ASHRAE COLOR CODE

NOTE: All other manufacturers; no known sensor codes

Case Control Systems

SENSOR COLORS

 

 

 

 

 

Manufacturer ® >

 

EIL

CPC

 

 

 

 

Location

 

 

 

 

 

 

 

Coil Inlet

Color

Blue

Blue

 

 

 

 

 

Part#

225-01-1755

225-01-3255

 

 

 

 

Coil Outlet

Color

Red

Red

 

 

 

 

 

Part#

225-01-1757

225-01-3123

 

 

 

 

Discharge Air

Color

Green

Green

 

 

 

 

 

Part#

225-01-1756

225-01-3260

 

 

 

 

Return Air

Color

Purple

Green

 

 

 

 

 

Part#

225-01-1758

225-01-3260

 

 

 

 

Defrost Term.

Color

White

Orange

 

 

 

 

 

Part#

225-01-0650

225-01-3254

 

 

 

 

Liquid Line

Color

White

Blue

 

 

 

 

 

Part#

225-01-0650

225-01-3255

 

 

 

 