Electrical
WIRING COLOR CODE
GREEN | GROUND |
PURPLE | |
ORANGE | LIGHTS |
YELLOW | RECEPTACLE |
RED / BLACK | |
BLACK / WHITE | |
BROWN | FAN MOTORS |
|
|
CASE MUST BE GROUNDED
NOTE: Refer to label affixed to case to determine the actual configuration as checked in the “TYPE INSTALLED” boxes.
ELECTRICAL CIRCUIT IDENTIFICATION
Standard lighting for all models will be full length fluorescent lamps located within the case at the top.
The switch controlling the lights, the plug provided for digital scale,and the thermometer are located at the rear of the case mullion.
The receptacle that is provided on the exterior back of these models is intended for computerized scales with a five amp maximum load, not for large motors or other high wattage appliances. It should be wired to a dedicated circuit.
HUSSMANN/CHINO now provides
NOTE: The total case electrical draw must not exceed 30 Amps ampacity at 115V in one connected lineup.
ELECTRICAL SERVICE RECEPTACLES (WHEN APPLICABLE)
The receptacles located on the exterior of the merchandiser are intended for scales and lighted displays. They are not intended nor suitable for large motors or other external appliances.
BEFORE SERVICING
Always Disconnect Electrical Power at the Main Disconnect when servicing or replacing any electrical component.
This includes (but not limited to) Fans, Heaters,
Thermostats, and Lights.
FIELD WIRING AND SERIAL PLATE AMPERAGE
Field wiring must be sized for component amperes printed on the serial plate.Actual ampere draw may be less than specified. Field wiring from the refrigeration control panel to the merchandisers is required for refrigeration thermostats. Most component amperes are listed in the “Case Specs” section, but always check the serial plate.
BALLAST LOCATION
Ballasts are located within the access panel that runs the length of the rear of the case. Refer to diagram on page 6.
WIRING AND SERIAL PLATE AMPERAGE
Field wiring must be sized for component amperes stamped on the serial plate. Actual ampere draw may be less than specified. Field wiring from the refrigeration control panel to the merchandisers is required for refrigeration thermostats. Most component amperes are listed in the "Case Specs" section, but always check the serial plate.
ASHRAE COLOR CODE
NOTE: All other manufacturers; no known sensor codes
Case Control Systems | SENSOR COLORS |
| |
|
|
|
|
Manufacturer ® > |
| EIL | CPC |
|
|
|
|
Location |
|
|
|
|
|
|
|
Coil Inlet | Color | Blue | Blue |
|
|
|
|
| Part# | ||
|
|
|
|
Coil Outlet | Color | Red | Red |
|
|
|
|
| Part# | ||
|
|
|
|
Discharge Air | Color | Green | Green |
|
|
|
|
| Part# | ||
|
|
|
|
Return Air | Color | Purple | Green |
|
|
|
|
| Part# | ||
|
|
|
|
Defrost Term. | Color | White | Orange |
|
|
|
|
| Part# | ||
|
|
|
|
Liquid Line | Color | White | Blue |
|
|
|
|
| Part# | ||
|
|
|
|
12