Innovator Door Installation and | P/N 0425683F |
Service Instruction |
|
|
|
|
|
!WARNING
Always disconnect the electrical power at the main disconnect when servicing or replacing any electrical component. This includes, but is not limited to, such items as doors, lights, fans, heaters, and thermostats.
LAMP (CENTER MULLION)
REPLACEMENT
Note: No additional parts need to be removed to change out the lamps
1. Turn off lights at switch.
2.Disengage the diffuser clips from the mullion by squeezing the diffuser cover at the clips. Two hands may be required as shown in Figure 19.
Diffuser Clip
Squeeze
Here
Light
Switch
Figure 19. Disengaging Diffuser Clips
3.Raise the diffuser slightly upward and out of the bottom filler. Twist the bottom of the diffuser toward the shelf and center of the door while lowering slightly to clear the honeycomb retainer. Pull the top of the diffuser toward the
HUSSMANN CORPORATION • BRIDGETON, MO | 11 |