GENERAL

Be sure merchandisers have been leveled according to the installation instructions shipped with the merchandiser.

The door nameplate is attached to the top of the door, handle side, behind the magnetic gasket.

The frame nameplate is located on the top left near the switch.

ALWAYS*CLEARGLASS

Hussmann recommends using a soft cloth with isopropyl (rubbing) alcohol to clean the inside (coated) glass surface. Isopropyl alcohol does not freeze and evaporates without leaving residue. Always allow the surface to dry before closing the door. Use of abrasives may damage the coated surface and void the warranty. Labels (stickers) applied to the coated surface will cause damage and void the warranty.

SHIPPING DAMAGE

All equipment should be thoroughly examined for shipping damage before and during unloading.

This equipment has been carefully inspected at our factory. Any claim for loss or damage must be made to the carrier. The carrier will provide any necessary inspection reports and/or claim forms.

NEW INSTALLATIONS

Untape the doors and remove the shipping braces located at top and bottom of the doors.

Doors are not fine adjusted at the factory since they will go out of adjustment during shipment. This is normal.

ADJUSTING CLOSING TORQUE

Adjust closing torque by turning the bottom hinge pin in the direction the door closes. Use a 1/2 in. (13 mm) wrench. Turn the hinge pin until the door closes on its own, usually 3 to 4 clicks or 3/4 turn. See Figure 1.

DO NOT over-torque the hinge spring assembly. Excessive torque (over 1 full turn) will result in damage to the spring assembly and/or door. If door does not close on its own after one full turn (5 clicks), look for obstructions causing the door to hang up.

Figure 1. Adjusting Closing Torque

HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM