Hand Held Device

PROTOCOL

 

DEFROST MENU

 

P/N 374511B

Page 23

3-DEFROST MENU

Press 3 on the Keypad to enter the Defrost sub- menu.

1- VIEW/SET ITEMS

Press 1 on the Keypad to enter the VIEW/SET ITEMS Submenu.

This screen shows three columns:

CIRCUIT lists the defrost circuit within the Protocol. The numbers 1 through 8 are fixed.

NAME refers to the description used to identify the defrost circuit.

STATUS lists the status of each defrost circuit.

REFR

=

In refrigeration

DEFR

=

In defrost

DATV =

DE-activated, will not defrost.

TERM =

Defrost terminated by temp.

N/A

=

Not Available or Not Installed

The horizontal arrows are used to activate or deactivate a circuit for defrost control, to force a circuit in or out of refrigeration or defrost go to the MAINTENANCE MENU. Note that the DATV status permanently disables the defrost function.

Use the vertical arrows to move up and down the circuit list.

PROTOCOL MAIN MENU

1-STATUS MENU

2-CONFIG MENU

3-DEFROST MENU

4-MAINT MENU

5-ALARM MENU

DEFROST MENU

1-VIEW/SET ITEMS

2-COPY SCHEDULE

3-ASSIGN OUTPUTS

4-ASSIGN CIRCUITS FOR SPLIT SUCT

 

DEFROST MENU

 

CIRCUIT

NAME

STATUS

1

CIRCUIT #1 NAME

REFR

2

CIRCUIT #2 NAME

DEFR

3

CIRCUIT #3 NAME

DATV

4

CIRCUIT #4 NAME

REFR

PRESS ENT TO SET

970307

HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 (Printed in U.S.A.)