I.C.T.C. Holdings Corporation PW2424-LD Start-Up And Operation Introduction, H.E.R.O. Industries

Models: PW2424-LD

1 11
Download 11 pages 28.82 Kb
Page 4
Image 4
START-UP AND OPERATION INTRODUCTION

START-UP AND OPERATION INTRODUCTION

1.Verify that the RED vented plug is installed in pressure washer pump as shown in Fig 1.

2.Before first use, check engine and pump oil levels.

Note: For shipping purposes, engine oil has not been added. Before each use, check engine oil level by unscrewing the oil dipstick. Add motor oil (consult Honda manual for correct oil grade) as required to bring to proper level, approximately mid-way on dipstick.

3.Check water supply volume. To operate correctly, the unit requires a water supply 25% greater than the units output.

( i.e. Model 3000 = 5 GPM, 2700 = 3 GPM,

2500 = 4.5 GPM, 2000 = 3.75 GPM of water flow ).

To test water supply output;

a)Turn water flow to full maximum output.

b)Place a 5 gallon pail or container under water flow for exactly 1 minute

 

( 60 seconds).

 

 

 

 

 

RED Vented

 

 

Fig. 1

 

c) Measure contents to determine water flow.

 

 

 

4.

Connect a standard garden hose to the water inlet or

 

 

 

 

 

 

 

bottom connection on the pump head ( Female hose

 

+

-

 

 

connector ). Fig. 2.

 

 

 

 

 

 

 

Pressure

 

 

 

 

5.

Connect the high pressure hose to the water “Outlet”

Control

 

 

or upper connection on the pump head.

 

 

 

 

 

 

 

( Male quick connect nipple). Fig. 2.

 

 

 

 

 

 

6.Turn the unloader knob on top of the pump head counter- clockwise to reduce the pressure prior to starting the machine.

7.Select the desired tip for the job. Insert tip into wand ( quick-connect fittings ). See page 6.

RED—0º,Narrow Fan, Direct or Concentrated Cleaning. YELLOW—15º,Medium Fan, General Use.

WHITE—40º,Wide Fan, Soft Pattern, For Rinsing. BLACK—65º,Chemical Injector Tip. Must be used when

operating chemical injector

 

Outlet

Injector

Inlet

 

8.If using injector system, insert BLACK spray tip and connect the detergent/chemical suction line to the fitting marked “Chem” and place the filter end into the chemical/detergent jug.

9.Turn on the water supply and trigger the spray gun to purge all air from the system, BEFORE starting engine.

10.Start the engine by following this procedure:

a.Turn the ON/OFF switch to ON.

b.Turn the GAS to ON.

c.Turn the CHOKE to FULL.

d.Push the THROTTLE lever to the ON position.

e.Pull the STARTING cord.

f.Once the engine has started, reduce the CHOKE until it is OFF, and open the THROTTLE to full ON. Use these instructions in conjunction with instructions provided in the Honda manual.

H.E.R.O. Industries

Page 4

Pressure Washer Owners

Page 4
Image 4
I.C.T.C. Holdings Corporation PW2424-LD Start-Up And Operation Introduction, H.E.R.O. Industries, Pressure Washer Owners