START-UP AND OPERATION INTRODUCTION
11.At this point, the gun is triggered to evacuate any remaining air in the system. Then trigger the gun and begin turning the red unloader knob in a clockwise direction as far as it will turn. You should now have full pressure.
12.To introduce chemicals/detergent to the spray, do the following;
a.Install “Black” injector tip.
b.Attach the chemical / detergent line to the fitting marked “Chem” and place the filter end into the chemical or detergent container.
c.Trigger the SPRAY GUN and chemical / detergent should start to flow out of gun.
SHUTTING DOWN THE MACHINE AFTER USE
1.Trigger the spray gun and reduce the pressure by turning the unloader knob
2.Turn engine switch to the OFF position.
3.Turn the throttle and gas levers to the OFF or Closed positions.
4.Shut OFF the water.
5.Trigger gun to remove any remaining pressure in the system.
6.Disconnect hose.
NOZZLE SELECTION
For your convenience, we have provided a selection of nozzles to choose from.
Your machine is equipped with a 0°, 15°, 40°, and a chemical nozzle.
If you require a different cleaning action, we suggest selecting the correct tip for the job.
1.RED = 0° Angle - High impact, solid stream.
2.YELLOW = 15° Angle - Narrow width spray pattern.
3.WHITE = 40° Angle - Wide width spray pattern.
4.BLACK = Chemical Injector
| 0° Angle | 15° Angle |
| 40° Angle | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
H.E.R.O. Industries
Page 5 | Pressure Washer Owners |