IBM 9483, 72H9623 Troubleshooting, Check Signal Cable message, The power LED is illuminated amber

Models: 9483 T56A 72H9623

1 41
Download 41 pages 34.06 Kb
Page 29
Image 29
Troubleshooting

Troubleshooting

Any horizontal noise appearing in any image or characters are not clearly portrayed.

The input signal data has not been optimized for the current operating mode. (Adjust the CLOCK PHASE by using the OSD function.)

Check Signal Cable message.

The signal cable is not connected.

Outside Range Limits message appears.

Picture is blank.

The frequency of the signal from the video card is outside the operating range of the monitor.

*Use the graphics board's utility software to change the frequency setting (Refer to the manual for graphics board).

*You can change the setup to the supported resolution using the Windows 95/98 Safety Mode (Press the F8 key during booting the system.) or see User Manual for equivalent messages in other relevant Operating Systems.

The power LED is illuminated amber.

Display power management mode.

There is no active signal coming from the PC.

The signal cable is not fastened securely.

Check the computer power and graphics adapter configuration.

The image on the SCREEN is not centered.

Image adjustment has not been performed for current mode. Select H position, V position and Clock via OSD and adjust to desired position.

The monitor does not enter the power saving off mode (Amber).

Computer video signal is not VESA DPMS standard. Either the PC or the video controller card is not using the VESA DPMS power management function.

Noise in 50% Grey Background might sometimes be difficult to totally eliminate using Clock & Clock Phase Controls.

Slight variations in timing from system unit’s graphics sub-system. [Via Desktop change background pattern to solid colour].

A17

Page 29
Image 29
IBM 9483, 72H9623, T56A Troubleshooting, Check Signal Cable message, Outside Range Limits message appears Picture is blank