Step 4. Apply Power to the Switch

Step 4. Apply Power to the Switch

The maximum current requirements are 10 amps at 100 VAC or 4.2 amps at 240 VAC.

Attach the AC power cords to the Power Supply blades and wall outlets or power strips. Secure the strain relief bales to the plugs. Place the On/Off switches in the On position.

The switch runs its self tests and begins normal operation – this may take a few minutes. Observe the Maintenance Panel and verify that the CPU0 blade Heartbeat LED is blinking about once per second and the Chassis Fault LED is NOT illuminated.

CHASSIS

 

CHASSIS

GOOD LED

 

FAULT LED

CPU0

HEARTBEAT

LED

Step 5. Verify Workstation Requirements

Verify that your workstation can support the Enterprise Fabric Suite 2007™ application with the following minimum requirements:

‰Windows® 2003 SP1/SP2/R2 and XP

‰256 MB memory minimum; 512 MB recommended

‰150 MB disk space

‰1 GHz processor

‰Video card with 256 colors

‰CD ROM drive, RJ-45 Ethernet port

‰Internet Browser: Microsoft® Internet Explorer® 5.0, Netscape Navigator® 6.0, Firefox® 1.0, or Mozilla™ 1.5

‰Java® 2 Standard Edition Runtime Environment 1.4.2

The default IP address of a new switch is 10.0.0.1. Ensure that your workstation is configured to communicate with the 10.0.0 subnet.