Jensen Tools XA250 Wiring, Power Terminal +12V, Remote Terminal REM, Ground Terminal GND

Models: XA250 XA275 XA2125

1 13
Download 13 pages 55.25 Kb
Page 5
Image 5
Wiring

XA2125, XA275, XA250

®

 

Wiring

Power

GND

REM

+ 12V

Power FUSE

BRIDGE Power Terminal (+12V)

R

R –

L

L

Power Terminal (+12V)

Connect directly to the vehicle battery+ terminal with 8 gauge wire (minimum).

Fuse

GND

REM

+ 12V

XA2125

60 AMP

 

 

XA275

30 AMP

 

 

Remote Terminal (REM)

Connect the power antenna/amplifier turn-on lead from the receiver to the AMPLIFIER REMOTE terminal.

XA250 25 AMP

Fuse or

Circuit Breaker

Spade

Connector

8 Gauge

Spade

Connector

Battery

Install as close

Terminal

to the battery

To Battery+

Terminal

Wire

18 Gauge

Adapter

as possible

To Receiver

Power

Wire

Antenna Lead

Ground Terminal (GND)

Connect to a good chassis ground. The ground connection should be to clean, unpainted metal to provide a good electrical connection.

Fuses

Use only blade-type fuses.

GND

REM

+ 12V

Spade

Sheet MetalConnector

Screw

8 Gauge

Wire

Drill 1/8" hole

in chassis

sheet metal

Remote Terminal (REM) FUSE Ground Terminal (GND)

Fuse

XA2125 30 AMP x 2

XA275 30 AMP x 1

XA250 25 AMP x 1

5

6236 XA2CH_E.p65

5

5/7/01, 2:07 PM

Page 5
Image 5