42 iSeries and AS/400e System Builder
#2794
#9794
#2794 2-line WAN IOA with Modem
The #2794/#9794 is a 2-line WAN with Modem adapter and is the CIM version, which is offered only in Australia and New
Zealand. Port 0 is the modem port and supports V.92 56K Async PPP, V.92 data modem, V.44 data compression, and V.34
Fax modem and Fax functions such as ECM and 2D/1D conversion. Port 0 does not provide sync modem capabilities
(SDLC and Sync PPP). Port 1 is the RVX port and supports multiple communications protocols.
Select one of the following cables to attach to port 0 (modem port):
򐂰#1019 Modem Cable-Australia
򐂰#1020 Modem Cable-China (Hong Kong S.A.R.)/New Zealand
Select one of the following cables to attach to port 1 (RVX port); #0348, #0349, #0353, #0354, #0356, #0359, #0360, #0365
or #0367. Select one of the following cables to attach to port 1 (RVX port):
򐂰#0348 V.24/EIA232 20-ft (6 m) PCI cable
򐂰#0349 V.24/EIA232 50-ft (15 m) PCI cable
򐂰#0353 V.35 20-ft PCI cable
򐂰#0354 V.35 50-ft PCI cable
򐂰#0355 V.35 80-ft/24 m PCI cable
򐂰#0356 V.36 20-ft PCI cable
򐂰#0358 V.36 150-ft/45 m PCI cable
򐂰#0359 X.21 20-ft PCI cable
򐂰#0360 X.21 50-ft PCI cable
򐂰#0365 V.24/EIA232 80-ft PCI cable
򐂰#0367 Operations Console PCI Cable
The #0367 cable ships with a 25-pin to 9-pin adapter. Multiple #0367 cables can be ordered (but only one per #2794) to
serve as consoles for secondary partitions when logical partitioning (#0140) is specified.
ECS is supported from the RVX port and one of the following cables is required to support ECS; #0348, #0349 or #0365.
ECS is supported from the Modem port (OS/400 V5R1 or later)
The #2794 does not support the remote ring indicate function. For further configuration information, see:
http://www.iseries.ibm.com/tstudio/planning/esa/esa.htm
See the “Soft rules: iSeries IOA requirements” topic in PCI Card Placement Rules for the IBM eServer iSeries Server,
REDP-3638 for additional restrictions.
Minimum operating system level: OS/400 V5R2