HTEB1

User manual

1.5 Jumpers and switches

JP1 is used for switching the serial interface from 1:1 to crossed connection. If you connect a 1:1 cable (like the cable that comes with the kit) use the default setting. If you connect a crossed cable set the jumper to alternate setting.

JP3 is used for the LCD-LED backlight. If the jumper is closed (1-2) the backlight will be ON. Remove the jumper (=open) if backlight operation is not necessary.

JP2 is used for I2C interface

JP4 is used as an output for the DAC or for PWM

JP1

Operation

1-3, 2-4

1:1 operation

1-2, 3-4

Crossed connection

 

 

JP3

Operation

Closed

LED backlight ON

Open

LED backlight OFF

 

 

JP2, I2C-CON

Operation

1

+5V

2

SDA

3

SCL

4

GND

 

 

JP4, D/A CON

Operation

1

D/A Output (PWM)

2

GND

Issue 0.2

Page 7

07/2002

Page 7
Image 7
IBM H8 user manual Jumpers and switches, JP4, D/A CON