Service Diagnosis |
| CD300 | |
Symptom | Probable Cause | Possible Correction |
|
Does not dispense. | No power to dispenser. | Check for power. | |
| Ice chute not all the way up. | Push ice chute up. | |
| No ice in hopper. | Check ice machine, it may | |
|
| be off or the dispenser’s | |
|
| storage capacity may have | |
|
| been exceeded. | |
| Dispenser | Move switch to ON position. | |
| Push button switch does not work. | Check switch, replace switch | |
|
| if it will not close. | |
| Coin switch does not work. | Check switch, replace switch | |
|
| if it will not close. | |
| Card switch does not work. | Check switch, replace switch | |
|
| if it will not close. | |
| Transformer failed. | ||
| Safety switch open. | Check switch, replace switch | |
|
| if it will not close. | |
| Relay has failed. | ||
|
| contacts are open | |
| Gear reducer motor is open or stuck. | Check motor, replace if open. | |
| Drive shaft broken. | Check drive shaft, replace if | |
|
| broken. | |
| Gear reducer stripped internally. | Check if motor turns but output | |
|
| shaft does not. Service or | |
|
| replace gear reducer. | |
Does not stop vending. | Vend or cam switch stuck. | Check cam or vend switch. | |
Ice chute fills by itself. | Result of ice agitation. | This is normal. | |
| Rotor not timed with cam switch. | Adjust cam switch. | |
| Vend switch stuck. | Check vend switch. |
Page 11