Operation and Adjustment | ICEU060 |
The information shown below covers a wide range of air and water temperatures. It is intended as a guideline only, and is based on data compiled from NEW Clean units. Allow a variation from each end of the range given.
Refrigeration System Pressures: | Freeze Cycle Time - | |
High Side (Discharge) |
| Defrost Cycle Time – |
End of Freeze Cycle | Compressor Amps | |
Harvest Cycle | Freeze Cycle – 3.6 to 4.3 | |
Low Side (Suction) |
| Harvest Cycle – 3.6 to 7.7 |
End of Freeze Cycle
Harvest Cycle (Max) 120 PSI
Adjustment Of The Cube Size
Adjust only when cubes are too large or too small.
(See the illustration at the right)
1.Remove the front panel, locate knob.
2.To increase the cube size, turn knob 1/8 turn clockwise. To decrease the cube size, turn the knob 1/8 turn counter clockwise.
3.Observe the size of the cubes in the next two harvest cycles. If more adjustment is needed, continue adjustments until the correct size is obtained.
Adjustment Of The Bin Thermostat Control
Adjust the bin thermostat when the icemaker turn off too soon (ice level low) or when it turns off too late (ice storage bin overfills.)
To increase the ice level in the storage bin:
1.Rotate the bin thermostat adjustment screw (located under the front panel on the control box cover) clockwise 1/8 turn at a time until the ice level that the machine maintains is correct.
2.Rotate the bin thermostat adjustment screw counterclockwise 1/8 turn at a time until the ice level is correct.