10 mm
q Slide the coupling ring over the coaxial cable. Strip the cable jacket and pull back to reveal 10 mm of braid.
• Soft solder the exposed braid and then pull out the jacket.
Coupling 30 mm
10 mm (soft solder)
w Strip the cable as shown below. Soft solder the cen- ter conductor the entire length of the exposed braid.
1–2 mm
soft solder

INSTALLATIONS 2

PL-259 connector

e Slide the connector body over the cable and sol- der as shown below.

Solder Solder

r Screw the coupling ring onto the connector body.

10mm 38 inches

Mounting

Attach the AT-140 either horizontally or vertically with one of the water drains facing downwards. After mounting, remove the screw in the water drain.

Mounting on a Mast/Metal pole

Mast/ Using U-bolts

Metal pole

U-bolt

U-bolt plate

Flat washer(L)

Spring washer

Flat washer(S)

Nut

WARNING: Mount the AT-140 securely with the supplied nuts and bolts. Otherwise, vibrations and shocks due to waves, etc. could loosen the antenna tuner making if fall, causing personal injury.

Mounting on a flat surface

Using nuts and bolts

Using self-tapping

 

screws

Nut

Flat washer(S) Spring washer

Flat washer(L)

Flat

Weatherproof cap

washer(L)

Drill a hole here

Hex head

Diameter:7–8 mm; 932516inches

bolt

4

Page 7
Image 7
Icom AT-140 instruction manual PL-259 connector