4 UNIT DESCRIPTION AND SPECIFICATIONS

Unit description

340 mm

 

80 mm

Ground terminal

 

 

Mounting plate

Water drain screw

 

Antenna cable receptacle

Control cable receptacle

Antenna terminal

Mounting plate

91.5 mm

Specifications

• Frequency coverage

: 1.6–30 MHz (with 7 m or longer antenna element)

• Power supply requirement

: 13.6 V DC (supplied from HF transceiver)

• Current drain

: Max. 2 A

 

• Operating temperature range

: –30°C to +60°C

 

• Weight (approx.)

: 2.5 kg

 

• Antenna connector

: SO-239 (50 )

 

• Max. Input power

: 150 W (PEP)

100 W (continuous)

• Automatic tuning time

: Approx. 2–3 sec. (general condition) Max. 15 sec.

 

Approx. 1 sec. (re-tuning for a memorized frequency)

• Automatic tuning accuracy

: SWR 2.0:1 (after tuning, except for multiples of 12 λ)

All stated specifications are subject to change without notice or obligation.

7