2 INSTALLATIONS
■Cable connections
qConnect the coaxial cable and the control cable to the
wCover both the antenna and the control cable con- nectors with rubber vulcanizing tape and fix it with a vinyl tape to prevent water seeping into the con- nector.
rConnect the coaxial cable and the control cable to the transceiver as illustrated below.
tGround the transceiver,
• See p. 2 for grounding details.
IMPORTANT!— AT-141
NEVER ground the AT141 via the mounting plate. It is not connected to ground internally.
Rubber vulcanizing tape
eFix both of the coaxial and control cables to pro- tect the inside connections.
DO NOT pull the antenna and control cable re-
ceptacles. This may cause disconnection (in the
AT-141),
connection.
Ground terminal
Mounting plate
Icom’s HF transceiver
Grounding
Grounding
5