SECTION 4 ADJUSTMENT PROCEDURES

4-1 PREPARATION

When adjusting the contents on page 4-9, a JIG CABLE (see illustration as shown below) is required.

Some adjustments must be performed on the “ADJUSTMENT MODE”. Entering the “ADJUSTMENT MODE”, see the next page.

REQUIRED TEST EQUIPMENT

 

 

 

 

 

 

 

 

 

EQUIPMENT

 

GRADE AND RANGE

EQUIPMENT

GRADE AND RANGE

 

DC power supply

 

Output voltage

: 13.6 V DC

Audio generator

Frequency range

: 300–3000 Hz

 

 

Current capacity

: 30 A or more

Output level

: 1–500 mV

 

 

 

 

 

 

 

 

 

 

 

 

 

RF power meter

 

Measuring range

: 1–100 W

Attenuator

Power attenuation

: 40 or 50 dB

 

 

Frequency range

: 0.5–30 MHz

Capacity

: 100 W or more

 

 

 

 

(terminated type)

 

Impedance

: 50

 

 

 

 

 

 

Frequency range

: 0.5–30 MHz

 

 

 

SWR

: Less than 1.2 : 1

Standard signal

 

 

 

 

 

Output level

: 0.1 µV–32 mV

 

 

 

Frequency range

: 0.1–600 MHz

generator (SSG)

 

 

 

 

(–127 to –17 dBm)

 

Frequency counter

 

 

 

 

 

Frequency accuracy

: ±1 ppm or better

 

 

 

 

 

 

 

 

 

DC voltmeter

Input impedance

: 50 k/V DC or better

 

 

 

Sensitivity

: 100 mV or better

 

 

 

 

 

 

 

 

 

FM deviation meter

 

Frequency range

: DC–600 MHz

Oscilloscope

Frequency range

: DC–20 MHz

 

 

Measuring range

: 0 to ±5 kHz

Measuring range

: 0.01–20 V

 

 

 

 

 

 

 

 

 

 

 

 

 

Digital multimeter

 

Input impedance

: 10 M/V DC or better

AC millivoltmeter

Measuring range

: 10 mV–10 V

 

 

 

 

 

 

 

 

CONNECTION

Standard signal

generator

CAUTION!

Modulation analyzer

Attenuator

Spectrum scope

DO NOT transmit while an SSG is connected to the antenna connector 1.

DC power supply

Ammeter

Distortion meter

 

Speaker

[MIC] connector

+_

1 7

2 8 6

3 4 5

to antenna connector 1/2

to antenna connector 1

RF power meter

to [SP]

to [CONTROLLER]

4 - 1