ICP DAS USA i-8000 Series manual 87KSERIES, 87K Digital I/O Modules Selection Guide

Models: i-8000 Series

1 48
Download 48 pages 10.47 Kb
Page 36
Image 36

i-87KSERIES

 

 

 

 

 

 

Serial Modules

 

 

 

 

 

87K Digital I/O Modules Selection Guide

 

Module

I-87040

I-87041

I-87051

I-87052

I-87053

 

 

 

 

 

 

8

16

Digital Input

 

 

 

 

 

differential

32

16

Isolation

Channels

Isolation

Isolation

 

 

(3750V)

 

 

 

(5000V)

 

 

 

 

 

 

 

Digital Output

 

 

32 (open

 

 

 

 

 

collector

 

Channels

 

 

 

Isolation)

 

 

 

Channels

32

16

8

16

Counter Input

 

100Hz

100Hz

100Hz

100Hz

Frequency

 

 

 

 

 

 

 

 

Safe Value

 

 

Yes

Power-on

 

 

Yes

Preset Value

 

 

 

 

 

 

 

 

 

Dual Watchdog

 

 

Yes

Yes

Yes

Yes

Yes

Timer

 

 

 

 

 

 

 

 

 

Availability

 

 

Y

Y

Y

Y

Y

Module

 

I-87054

I-87055

 

I-87057

I-87058

Digital Input

8

 

 

 

8

 

Isolation

8

 

differential

Channels

 

 

Isolation

 

(3750V)

 

 

 

 

 

 

 

 

(5000V)

Digital Output

 

8 (open

8 (open

 

16 (open

 

 

collector)

collector

 

collector)

Channels

 

Isolation

Isolation)

 

Isolation

 

 

 

 

 

(3750V)

(3750V)

 

(3750V)

 

Channels

8

8

 

8

Counter Input

 

 

100Hz

100Hz

 

100Hz

Frequency

 

 

 

 

 

 

 

 

 

 

Safe Value

 

 

Yes

Yes

 

Yes

Power-on

 

 

Yes

Yes

 

Yes

Preset Value

 

 

 

 

 

 

 

 

 

 

Dual Watchdog

 

 

Yes

Yes

 

Yes

Yes

Timer

 

 

 

 

 

 

 

 

 

 

Availability

 

 

Y

Y

 

Y

Y

3-36