Format Error Messages

2030 SCAN less than 1

An invalid scan setting exists in the file. Reedit the scan setting.

2040 SCAN greater than 2

An invalid scan setting exists in the file. Reedit the scan setting.

2050 Horizontal total too small

The generator does not support a horizontal period (active

+blanked) less than 144 pixels per horizontal scan line.

Increase the horizontal period so that it’s more than 143 pixels.

2060 Horizontal total too large

The generator does not support a horizontal period (active

+blanked) of more than 4096 pixels per horizontal scan line.

Decrease the horizontal period so that it’s less than 4096 pixels.

2071 Pixel rate too high

The pixel rate exceeds the maximum rate supported by the currently selected generator model for the given video type selection.

Make sure video type is correct.

Decrease the pixel rate.

Decrease the horizontal period (in pixels) for a given horizontal rate.

2072 Pixel rate too high

The pixel rate exceeds the maximum rate supported by the currently selected generator model for the given video type selection.

Make sure video type is correct.

Decrease the pixel rate.

Decrease the horizontal period (in pixels) for a given horizontal rate.

8-7

Page 315
Image 315
Quantum Data 801GC, 801GF, 801GX manual Format Error Messages