Power-on

Normalpower-on

Power-on message remains

Under normal conditions, the power light will come on as soon as the 801G* is turned on. The following message will be the first thing to appear in the LCD just after the generator is powered-up:

The top number indicates the operating firmware revision level, while the bottom number indicates the hardware revision level. Please note these num- bers if you will be contacting Quantum Data with any questions or problems concerning the operation of the unit.

If no problems are encountered, the generator will output the format and test image that were active when the unit was last powered down.

If the last active image was animated, the LCD will continue to display the firmware and hardware re- vision levels until a button is pushed or a knob is turned. Otherwise, the display will change by itself after about two seconds.

The information that next appears will depend upon the operating mode that has been programmed into the 801G*. The left-hand example shown below is typical for the normal (default) operating mode of the 801G*. The example on the right shows a typical display in the test sequence mode.

Horizontal Rate (To nearest KHz)

Vertical Rate (To nearest Hz)

H31 15=VGA_m18

V60 18=Grill_11

Signal Format Number

Signal Format Name

Test Image Name

Test Image Number

7-2

Chapter 7: Troubleshooting

Model 801GC, 801GF & 801GX ¥ Rev. A

Page 306
Image 306