Quantum Data 801GC, 801GF, 801GX manual Line Voltage Selector, Selecting a line voltage

Models: 801GC, 801GF, 801GX

1 356
Download 356 pages 47.77 Kb
Page 114
Image 114

Line Voltage Selector

Make certain that the voltage selector switch is set correctly before plugging the 801G* in.

Operating the 801G* with the wrong AC line voltage setting or adjusting the line voltage se- lector switch while the generator is plugged in may cause serious damage to the generator. This type of damage is not covered under the prod- uct warranty nor service contracts.

You will find a recessed AC line voltage selector on the left side of the 801G* cabinet. This selector has two positions:

115V - for use with line voltages between 86 and 132 VAC @ 48 to 66 Hz

230V - for use with line voltages between 180 and 250 VAC @ 48 to 66 Hz

The 801G* is shipped from the factory with the line voltage selector set for 115V.

If the voltage in your area is greater than 180V, you must adjust the voltage selector to 230V before plugging in the generator.

Selecting a line voltage .

The line voltage selector can be changed using a pen, screwdriver, or similar pointed tool.

1.Make sure that the 801G* power cord is un- plugged.

2.Insert tool into the voltage selector slot.

3.Push against the side of the slot closest to the voltage label.

4.Slide the selector toggle until the correct line voltage comes into full view.

5-2

Chapter 5: Making Connections

Model 801GC, 801GF & 801GX ¥ Rev. A

Page 114
Image 114
Quantum Data 801GC, 801GF, 801GX manual Line Voltage Selector, Selecting a line voltage