Quantum Data 801GC, 801GF, 801GX manual Seqn, SEQuence New, Seqp, SEQuence Path, 162

Models: 801GC, 801GF, 801GX

1 356
Download 356 pages 47.77 Kb
Page 288
Image 288

SEQN

SEQuence New

Classification:

Sequence editor control

Command Syntax:

SEQN [<name>]

Limits:

<name> = optional valid MS-DOS filename

 

(8 characters minus any extension)

Query Syntax:

SEQN?

Query Response:

<name>

Description:

The SEQN command initializes the sequence edit buffer. The

 

name <name> is assigned as the sequence’s name. The query

 

will return the name that has been assigned as the sequence’s

 

name.

Other Required Cmds:

None

E x a m p l e s :

S E Q N / / I n i t e d i t b u f f e r w i t h o u t

 

/ / a s s i g n i n g a n e w n a m e

 

or

 

S E Q N M Y _ S E Q / / I n i t e d i t b u f f e r w i t h

 

/ / n a m e o f " M Y _ S E Q "

SEQP

SEQuence Path

Classification:

Sequence memory management

Command Syntax:

SEQP <name>

Limits:

<name> = a valid MS-DOS filename

 

(8 characters minus any extension)

Query Syntax:

SEQP?

Query Response: Current sequence path name

Description:

The FMTP command sets the current image path name to a

 

given directory. The query will return the current image path

 

name.

Other Required Cmds:

None

Example:

S E Q P B U R N / / S e q u e n c e s i n B U R N d i r e c t o r y

 

/ / w i l l b e l i s t e d

6-162

Chapter 6: Programming

Model 801GC, 801GF & 801GX¥Rev. A

Page 288