2321 Vertical active must be even when in inter- laced scan mode

The generator does not support vertical active periods (in lines) that cannot be evenly divided by two (2) when interlaced operation is selected.

Make the vertical active period (in lines) evenly divisible by 2.

Change to progressive (non-interlaced) scan mode.

2330 Vertical blanking too small

There must be at least 3 lines of vertical blanking with interlaced operation.

Increase the vertical period.

Decrease vertical active.

Switch to non-interlaced operation.

2350 Vertical pulse too small

The generator does not support a vertical sync pulse width value of less than one scan line in duration. The firmware makes the pulse a half-line shorter than the entered value when European type sync is selected.

Increase the vertical sync pulse width.

2370 Vertical pulse too large

The generator does not support a vertical sync pulse width greater than the number of blanked scan lines per frame with non-interlaced operation.

Decrease the value of vertical sync pulse width.

Increase the value of vertical period (in lines).

Decrease vertical active.

2390 Vertical pulse too large

The generator does not support a vertical sync pulse width greater than the least number of blanked scan lines ((Vper

-Vact - 1) ⎟ 2 ) between fields with interlaced operation.

Decrease the value of vertical sync pulse width.

Increase the value of vertical period (in lines).

Decrease vertical active.

8-12

Chapter 8: Error Messages

Model 801GC, 801GF & 801GX¥Rev. A

Page 320
Image 320