will power-up in the sequence mode with the selected sequence. However, loading another sequence file with the upper knob, will not al- low you to get back to the original power-up sequence file.

Cancelling the Sequence Mode

You cancel the power-up sequence mode with the following steps:

Power-up the 801G* in the programming mode (“Image” button held down on power-up).

Select the sequence knob directory editor.

Press the “Modify” button. It does not matter which sequence file is selected in the right hand column. The will put you in the sequence edi- tor.

Press the Mode button at least one time. Keep pressing and releasing the button until the “Mode:” label to the right of the sequence name goes away.

Turn off the power.

The next time the 801G* is turned on, it will be in the normal operating mode. The top knob will se- lect formats and the bottom knob will select images.

6-42

Chapter 6: Programming

Model 801GC, 801GF & 801GX¥Rev. A

Page 168
Image 168
Quantum Data 801GC, 801GF, 801GX manual Cancelling the Sequence Mode