Quantum Data 801GC, 801GF, 801GX manual Fmtr, Fmts

Models: 801GC, 801GF, 801GX

1 356
Download 356 pages 47.77 Kb
Page 251
Image 251

FMTR

ForMaT Read from memory location (by

 

number)

 

Classification:

Format memory management

Command Syntax:

FMTR <location>

Limits:

<location> = 1 through 300 (RAM) or -1 through -24

 

(EPROM)

 

Query Syntax:

FMTR? <location>

Query Response:

<name>

 

Description:

Reads format from the format memory location into the format

 

buffer. The FMTR command does not reconfigure the signal

 

generating hardware. The FMTR? query returns the <name> of

 

the format stored in location <location>. FMTR? returns the

 

string EMPTY if the format memory location <location> is empty.

Other Required Cmds:

The ALLU command updates the hardware to the new settings

 

and redraws the test image.

Example:

F M T R - 5

/ / L o a d f o r m a t f r o m R O M l o c a t i o n

 

/ /

5

 

A L L U / / U p d a t e h a r d w a r e a n d r e d r a w

 

/ / i m a g e

FMTS

ForMaT Save

Classification:

Format memory management

Command Syntax:

FMTS

Description:

The FMTS command saves the current format edit buffer contents

 

into format memory using the current name of the format in

 

the edit buffer.

Other Required Cmds:

None

Example:

FMTS

6-125

Page 251
Image 251