HSIZ

Horizontal SIZe

Classification:

Format parameter setting

Command Syntax:

HSIZ <physical size> (context sensitive - see FMTB and

 

FMTE)

Limits:

<physical size> = positive value

 

(floating point accepted)

Query Syntax:

HSIZ?

Query Response:

<physical size> (floating point returned)

Description:

The HSIZ command establishes the horizontal physical size of

 

the image on the display. Units expected (or returned) vary

 

according to the last mode set with USIZ command. The HSIZ

 

command is context sensitive and must appear between begin

 

and end commands: FMTB and FMTE. The HSIZ? query returns

 

the current setting of HSIZ.

 

 

 

 

Note – Make sure that the USIZ parameter is properly set before

 

using the HSIZ command. Changing the USIZ setting after

 

entering HSIZ will convert the size to match the new unit of

 

measure.

 

Other Required Cmds:

The units of measure must be properly set by USIZ before entering

 

HSIZ. The ALLU command updates hardware to the new setting

 

and redraws the test image, taking the new size into account.

Example: F M T B / / B e g i n e d i t i n g s e s s i o n O n e o r / / m o r e f o r m a t e d i t i n g c o m m a n d s / / . . .

U S I Z 1 / / S e l e c t i n c h e s a s u n i t o f / / m e a s u r e i n b u f f e r

H S I Z 1 0 . 4 / / S e t w i d t h t o 1 0 . 4 i n / / b u f f e r

V S I Z 7 . 8 / / S e t h e i g h t t o 7 . 8 i n b u f f e r A L L U / / T e s t t h e n e w s e t t i n g s

/ / O n e o r m o r e f o r m a t e d i t i n g

// c o m m a n d s

// . . .

F M T E / / E n d o f e d i t i n g s e s s i o n

6-136

Chapter 6: Programming

Model 801GC, 801GF & 801GX¥Rev. A

Page 262
Image 262