PUTR

PUT Relative

Classification:

Direct processor control

Command Syntax:

PUTR <value>

Limits:

<value> = 0 to 2^(SIZE)-1

Query Syntax:

None

Description:

The PUTR command writes the specified value <value> into

 

the location pointed to by the address register (see the ADDR

 

command). The parameter <value> is interpreted according to

 

the current setting of BASE (see the BASE command). The number

 

and format of the bits written depend on the current setting of

 

S I Z E ( s e e t h e S I Z E c o m m a n d ) . T h e a d d r e s s r e g i s t e r i s

 

automatically incremented by SIZE bits after the current location

 

has been written to.

 

 

 

 

Note – This command will normally be used only with custom

 

applications and command files created by Quantum Data.

 

Indiscriminate use of this command can cause the generator to

 

stop operating and / or the loss of stored data in nonvolatile

 

RAM.

 

Other Required Cmds: PUTR expects parameters formatted according to the current radix set by the BASE command.

Example: U s e o n l y w i t h c o d e s u p p l i e d b y Q u a n t u m Data!

RATC

pixel RATe Calibration factor

Classification:

System parameter setting

Command Syntax:

RATC <factor>

Limits:

<factor> = Floating point number equal to calibration factor

 

Typical min. = 0.99990

 

Typical max = 1.00010

Query Syntax:

RATC?

Query Response:

<factor>

Description:

The RATC command sets an internal multiplication factor used

 

in setting the pixel clock frequency. The multiplication factor

 

can be set to compensate for the frequency error of the internal

 

reference crystal. Having to use a factor outside of the typical

 

range may indicate a failure of generator’s hardware. Re-

 

initializing the generator’s memory sets the calibration factor

 

to a factory-default setting of 1.00000.

 

 

 

 

Note – The RATC parameter is a system level parameter that

 

will affect the pixel clock frequency of all Formats that are

 

recalled. The RATC value will be retained when the generator

 

is powered down and back up again. Query the current setting

 

of RATC if you are experiencing problems with the pixel clock

 

or scan rate being off in frequency.

 

Other Required Cmds:

None

Example:

R A T C 1 . 0 0 0 0 7 / / I n c r e a s e s p i x c l k b y

 

/ / f a c t o r o f 1 . 0 0 0 0 7

6-157

Page 283