Quantum Data 801GC, 801GF, 801GX manual Imgn, IMaGe New, Imgp, IMaGe Path, 142

Models: 801GC, 801GF, 801GX

1 356
Download 356 pages 47.77 Kb
Page 268
Image 268

IMGN

IMaGe New

Classification:

Image editor control

Command Syntax:

IMGN [<name>]

Limits:

<name> = optional valid MS-DOS filename

 

(8 characters minus any extension)

Query Syntax:

IMGN?

Query Response:

<name>

Description:

The IMGN command initializes the image edit buffer. The name

 

<name> is assigned as the image’s name. The query will return

 

the name that has been assigned as the image’s name.

Other Required Cmds:

None

E x a m p l e s :

I M G N / / I n i t e d i t b u f f e r w i t h o u t

 

/ / a s s i g n i n g a n e w n a m e

 

or

 

I M G N M Y _ I M G / / I n i t e d i t b u f f e r w i t h

 

/ / n a m e o f " M Y _ I M G "

IMGP

IMaGe Path

Classification:

Image memory management

Command Syntax:

IMGP <name>

Limits:

<name> = a valid MS-DOS filename

 

(8 characters minus any extension)

Query Syntax:

IMGP?

Query Response:

<name>

Description:

The FMTP command sets the current image path name to a

 

given directory. The query will return the current image path

 

name.

Other Required Cmds:

None

Example:

I M G P F O C U S / / L i s t I m a g e s i n F O C U S d i r