2398 Invalid DSS type

An invalid digital separate sync type selection exists in the file.

Reedit the digital separate sync type setting.

2399 Invalid sync type

An invalid sync select exists in the file. Reedit the sync select setting.

2400 Digital separate sync type selection not compatible with analog and/or digital sync type

The generator does not support the given combination of digital separate sync (H&V) selection with one or both of the analog or digital composite sync type selections.

Select only one sync type.

2430 Vertical pulse delay extends sync beyond blanking

The generator does not support vertical sync pulses with any portion of the pulse occurring outside of the vertical blanking period.

Decrease the vertical sync pulse width.

Decrease the vertical sync pulse delay.

Increase the vertical period (in lines).

Decrease the vertical active (in lines).

2450 Vertical pulse delay extends sync beyond blanking

The generator does not support vertical sync pulses with any portion of the pulse occurring outside of either vertical blanking period with interlaced operation.

Decrease the vertical sync pulse width.

Decrease the vertical sync pulse delay.

Increase the vertical period (in lines).

Decrease the vertical active (in lines).

8-14

Chapter 8: Error Messages

Model 801GC, 801GF & 801GX¥Rev. A

Page 322
Image 322
Quantum Data 801GC, 801GF, 801GX Invalid DSS type, Invalid sync type, Vertical pulse delay extends sync beyond blanking