68K System Monitor

User's Guide

GE Energy Services

Error Messages

Introduction

 

68K Monitor returns several general error messages resulting from input or syntax

 

 

errors in the command input, or system or test failures during execution.

 

 

These error messages are identified below:

 

 

 

 

 

 

Message

 

The most general error is an incorrect number of arguments for the command

Summary

 

defined. This error causes a display of the correct use of the specified function.

 

 

Other possible error messages are listed below:

 

 

 

 

 

 

 

This Message

is displayed when…

 

 

 

 

 

 

 

 

Application which

a process or user requests an exit command, but the

 

 

 

activated the monitor

process that called 68K Monitor is suspended or

 

 

 

has been deleted! (or

deleted.

 

 

 

suspended)

 

 

 

 

 

 

 

 

 

 

Breakpoint defined!

the specified address is already defined as a breakpoint,

 

 

 

 

the monitor will display this message when defining a

 

 

 

 

new breakpoint (DB).

 

 

 

 

 

 

 

 

Breakpoint not

a breakpoint was not encountered when attempting a

 

 

 

suspended!

resume (RB) or step (SB) breakpoint command.

 

 

 

 

 

 

 

 

Cannot post to

a send (SX) or jam (JX) exchange command encounters

 

 

 

exchange!

an error in sending the message to the specified

 

 

 

 

exchange.

 

 

 

 

 

 

 

 

Command aborted!

the user replied NO when asked to verify a Return to

 

 

 

 

BootROM (RTB) command.

 

 

 

 

 

 

 

 

Command not found!

the specified command is not located within 68K

 

 

 

 

Monitor’s command list.

 

 

 

 

 

 

 

 

FLASH invalid!

a directory (DIR) command on a FLASH default

 

 

 

 

database fails (i.e., no default database could be

 

 

 

 

detected).

 

 

 

 

 

 

 

 

Invalid ID!

the monitor cannot find the specified identification, or it

 

 

 

 

is incorrect. The ID can be a breakpoint number,

 

 

 

 

communications port, table name, or process or

 

 

 

 

exchange ID

 

 

 

 

 

 

 

 

Invalid switch!

the user does not specify the mode for the chosen

 

 

 

 

function.

 

 

 

 

 

 

 

 

No free breakpoints!

the define breakpoint (DB) command is attempted when

 

 

 

 

all available breakpoints are in use.

 

 

 

 

 

 

 

 

Numeric input error!

a numeric field contains non-numeric characters.

 

 

 

 

 

 

 

 

 

 

 

 

 

Continued on next page

 

 

 

 

 

 

 

General

 

 

SWM0023-1.00 -2

Full Release

1-7

 

Page 17
Image 17
GE 68K System manual Error Messages