68K System Monitor
User's Guide | GE Energy Services |
Error Messages
Introduction |
| 68K Monitor returns several general error messages resulting from input or syntax | |||
|
| errors in the command input, or system or test failures during execution. | |||
|
| These error messages are identified below: | |||
|
|
|
|
|
|
Message |
| The most general error is an incorrect number of arguments for the command | |||
Summary |
| defined. This error causes a display of the correct use of the specified function. | |||
|
| Other possible error messages are listed below: | |||
|
|
|
|
| |
|
| This Message | is displayed when… |
| |
|
|
|
|
| |
|
| Application which | a process or user requests an exit command, but the |
| |
|
| activated the monitor | process that called 68K Monitor is suspended or |
| |
|
| has been deleted! (or | deleted. |
| |
|
| suspended) |
|
|
|
|
|
|
|
| |
|
| Breakpoint defined! | the specified address is already defined as a breakpoint, |
| |
|
|
| the monitor will display this message when defining a |
| |
|
|
| new breakpoint (DB). |
| |
|
|
|
|
| |
|
| Breakpoint not | a breakpoint was not encountered when attempting a |
| |
|
| suspended! | resume (RB) or step (SB) breakpoint command. |
| |
|
|
|
|
| |
|
| Cannot post to | a send (SX) or jam (JX) exchange command encounters |
| |
|
| exchange! | an error in sending the message to the specified |
| |
|
|
| exchange. |
| |
|
|
|
|
| |
|
| Command aborted! | the user replied NO when asked to verify a Return to |
| |
|
|
| BootROM (RTB) command. |
| |
|
|
|
|
| |
|
| Command not found! | the specified command is not located within 68K |
| |
|
|
| Monitor’s command list. |
| |
|
|
|
|
| |
|
| FLASH invalid! | a directory (DIR) command on a FLASH default |
| |
|
|
| database fails (i.e., no default database could be |
| |
|
|
| detected). |
| |
|
|
|
|
| |
|
| Invalid ID! | the monitor cannot find the specified identification, or it |
| |
|
|
| is incorrect. The ID can be a breakpoint number, |
| |
|
|
| communications port, table name, or process or |
| |
|
|
| exchange ID |
| |
|
|
|
|
| |
|
| Invalid switch! | the user does not specify the mode for the chosen |
| |
|
|
| function. |
| |
|
|
|
|
| |
|
| No free breakpoints! | the define breakpoint (DB) command is attempted when |
| |
|
|
| all available breakpoints are in use. |
| |
|
|
|
|
| |
|
| Numeric input error! | a numeric field contains |
| |
|
|
|
|
| |
|
|
|
| ||
|
|
| Continued on next page |
| |
|
|
|
|
|
|
General |
|
|
Full Release | |
|