68K System Monitor
User's Guide GE Energy Services
General SWM0023-1.00 -2
Full Release 3-13
CCB - Create Configuration Storage Block, Continued
Parameters (continued)
Example Type ccb 600000 100000 400 2 and press ENTER.
Results: The monitor creates a configuration storage control
block at address 0x600000, taking the next 0x100000
bytes as the space for the configuration storage
system.
After allocating the size of the storage control
structures and the 0x400 bytes for the response file,
the command divides the remaining space into two
equal slices to store configurations.
Special
Considerations
Use this command primarily when the system first initializes,
in order to set up the configuration storage space. After that, it