CCB - Create Configuration Storage Block, Continued

Parameters (continued)

 

Example

Type ccb 600000 100000 400 2 and press ENTER.

 

 

 

Results: The monitor creates a configuration storage control

 

 

 

block at address 0x600000, taking the next 0x100000

 

 

 

bytes as the space for the configuration storage

 

 

 

system.

 

 

 

After allocating the size of the storage control

 

 

 

structures and the 0x400 bytes for the response file,

 

 

 

the command divides the remaining space into two

 

 

 

equal slices to store configurations.

 

 

 

 

 

 

Special

Use this command primarily when the system first initializes,

 

 

Considerations

in order to set up the configuration storage space. After that, it

 

 

 

expects to be only rarely invoked.

 

 

 

 

 

 

 

 

 