68K System Monitor

GE Energy Services

User's Guide

 

 

TR - Trace, Continued

Syntax (continued)

 

Example 1

Type tr /r 20 /t0 10 208000 = 12345678 and press ENTER.

 

 

 

Results: This will allocate a buffer for 20 samples and

 

 

 

triggers when the long memory location becomes

 

 

 

12345678. It saves 10 samples before the trigger, the

 

 

 

trigger sample and 9 samples more to fill the buffer.

 

 

 

 

 

 

Example 2

Type tr /r 20 /t0 10 208000 change and press ENTER.

 

 

 

Results: This triggers if the long memory location changes

 

 

 

value.

 

 

 

 

 

 

Example 3

Type tr /r 20 /t0 10 208000 != 12345678 and press ENTER.

 

 

 

Results: This triggers if long memory value changes from the

 

 

 

value 12345678.

 

 

 

 

 

 

Example 4

Type tr /r 20 /t1 10 00123456 and press ENTER.

 

 

 

Results: This triggers when the RTC value if greater than or

 

 

 

equal to 00123456.

 

 

 

 

 

 

Example 5

Type tr /r 20 /t2 10 30123456 and press ENTER.

 

 

 

Results: This triggers after the process with the ID of

 

 

 

30123456 runs.

 

 

 

 

 

 

Special

This function is only available as a special debug BootROM as

 

 

Considerations

there is not enough room for it to be permanently included.

 

 

 

Currently, the BootROM code must have the TRACE

 

 

 

command compiled into S043-0 before you can use this

 

 

 

command. You will have to remove some other commands in

 

 

 

order to make room for it.

 

 

 

 

 

 

 

 

 

SWM0023 1.00 2