Page 13

Testing the Voltage Function

To verify accuracy in the DC and AC voltage ranges, do the following:

1.Connect the Calibrator to the VΩ and COM inputs on the Meter.

2.Set the Calibrator for the voltage from step 1 to 5 in Table 1.

Compare the reading on the Meter display with the display reading shown in Table 1. If the display reading falls outside of the range shown in Table 1, the Meter does not meet specification.

Table 1. DC Voltage Test

 

Input

 

Reading

Step

Voltage

61-633

 

61-635

1

3.6000V

3.5908 to 3.6092

 

3.5958 to 3.6042

2

-3.6000V

-3.5908 to -3.6092

 

-3.5958 to -3.6042

3

36.000V

35.908 to 36.092

 

35.954 to 36.042

4

360.00V

359.08 to 360.92

 

358.58 to 360.42

5

900V

896.2 to 903.8

 

897.46 to 902.54

3.Press the blue button on the Meter to toggle to ACV function.

4.Set the calibration for the voltage and frequency from step 1 to 17 in Table 2. Compare the reading on the Meter display with the display reading shown in Table 2. If the display reading falls outside of the range shown in Table 2, the meter does not meet specification.

Table 2. AC Voltage Test

 

Input

 

 

Reading

 

 

 

 

 

 

Step

Voltage

Frequency

61-633

 

61-635

 

 

 

 

 

 

1

3.6000V

50Hz

3.5590 to 3.6410

 

3.5698 to 3.6302

 

 

 

 

 

 

2

3.6000V

1KHz

3.5230 to 3.6770

 

3.5590 to 3.6410

 

 

 

 

 

 

3

3.6000V

10KHz

3.4860 to 3.7140

 

3.5220 to 3.6780

 

 

 

 

 

 

4

3.6000V

20KHz

N.A

 

3.4850 to 3.7150

 

 

 

 

 

 

5

3.6000V

50KHz

N.A

 

3.4120 to 3.7880

 

 

 

 

 

 

6

36.000V

50Hz

35.518 to 36.482

 

35.698 to 36.302

 

 

 

 

 

 

7

36.000V

1KHz

35.230 to 36.770

 

35.590 to 36.410

 

 

 

 

 

 

8

36.000V

10KHz

34.320 to 37.680

 

35.220 to 36.780

 

 

 

 

 

 

9

36.000V

20KHz

N.A

 

34.850 to 37.150

 

 

 

 

 

 

10

36.000V

50KHz

N.A

 

34.120 to 37.880

 

 

 

 

 

 

11

360.00V

50Hz

355.18 to 364.82

 

356.98 to 363.02

 

 

 

 

 

 

12

360.00V

1KHz

352.30 to 367.70

 

355.90 to 364.10

 

 

 

 

 

 

13

360.00V

10KHz

348.60 to 371.40

 

352.20 to 367.80

 

 

 

 

 

 

14

360.00V

20KHz

N.A

 

348.50 to 371.50

 

 

 

 

 

 

15

360.00V

50KHz

N.A

 

341.20 to 378.80

 

 

 

 

 

 

16

720.0V

50Hz

706.4 to 733.6

 

709.96 to 730.04

 

 

 

 

 

 

17

720.0V

1KHz

699.6 to 740.4

 

703.20 to 736.80

 

 

 

 

 

 

Form Number TM61633-5