IFB Appliances ELENA EX manual Technical Data, Water Inlet, Water Outlet, Electrical Connection

Models: ELENA EX

1 16
Download 16 pages 58.34 Kb
Page 7
Image 7
TECHNICAL DATA

TECHNICAL DATA

Dimensions(DxWxH)

: 56 cm x 60 cm x 85 cm

Weight

:

57 kgs

Capacity

: 5 Kgs of dry clothes (cotton)*

Programmes

:

10 wash care programmes

Water Inlet

1.Connect inlet hose to water tap/line.

2.Do not connect machine to a hot water supply.

WATER INLET

DRAIN

PIPE

Selector Buttons

:

On/Off, 600C.

Spin Speed

:

600 rpm

Heater Rating

:

1.9 kW

Drum

:

Stainless Steel

Temperature Selection

:

600C

Drain Pump Rating

:

30 W

Water Consumption

: 75 litres for normal wash.

Water Outlet

1.A drain pump is provided in the machine to pump out used water.

2.The end of the outlet should be placed near a drain. If necessary, it can be placed over the edge of a sink at a maximum height of 1 mt. from the floor level.

3.Allow free flow of water from the outlet pipe.

DRAIN

PIPE

WATER INLET

Power Consumption

:

0.25 unit for cold wash

Cotton Wash Programme :

0.6 - 0.9unit hot wash at 600C

Connected Load

:

2.35 KW Max.

Programme Duration

:

50 to 115 minutes

Power supply

:

220 - 240 V, Single Phase, 50 Hz

Water Pressure

:

1 bar ( 1.03 kg/cm2 ) - 10 bar ( 10.3

 

 

kg/cm2)

Specifications are subject to change without prior notice.

*Capacity depends on size, texture and combination of clothes

Depending on water pressure, Water hardness, Water inlet Temperature, Quantity and type of textile, Detergents used, Degree of soiling, Ambient condition, selected additional functions & power supply fluctuations the actual values given on or with the machine can deviate from the declared standard values, as they are tested according to the laboratory conditions

28

Electrical Connection

qCheck that the electrical line take the required

load.

qConnect to a 230V, 50Hz single phase AC supply. The appliance must be positioned so that the plug is accessible.

qMachine must be earthed properly before operation. This can be done by using a 3 - pin plug and a properly earthed operated socket of 16 Ampere rating.

qIf the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard. It should not be stretched when connected to the main socket.

9

16 AMPS

Water Inlet X

X

Page 7
Image 7
IFB Appliances ELENA EX manual Technical Data, Water Inlet, Water Outlet, Electrical Connection