Using the Controls

 

 

 

 

On/Off Valve

Display

Air Controls

Air Control 4

 

Invert Button

1, 2, and 3

 

 

 

 

 

Display

Pump

Pump

Light

Temperature

Button 1

Button 2

Button

Buttons

1

 

1

On/Off

2

1

2

Valve

3

 

 

 

 

4

3

 

1

3

 

 

 

 

4

 

4

 

Pump Button 2: Turns the spa jets labeled 1 and 2 (at the left) on and off. If the button is pressed once, the jets will run, providing soothing hydrotherapy. If the button is pressed again, the jets will shut off.

The spa also features an automatic mode that heats and filters the water when the spa is left unattended. When the power to the spa is first turned on, or if the water temperature is below the set temperature, the water will be heated as required. Note: To keep the filter and heat cycles from running, the power to the spa must be turned off.

Light Button: Turns the underwater light on and off.

Air Control 1: Determines the amount of air flowing through the hydrotherapy jets labeled 1 (above). If the control is turned counterclockwise, the amount of air will increase; if the control is turned clockwise, the amount of air will decrease. Air controls 2–4 function in the same manner.

Air Controls 2, 3, and 4: Determine the amount of air flowing through the hydrotherapy jets labeled 2, 3, and 4 (above).

Display Invert Button: Turns the display 180°, allow- ing it to be read from inside or outside of the spa.

Pump Button 1: Turns the spa jets labeled 3 and 4 (above) on high, low, and off. If the button is pressed once, the pump will run at high speed. If the button is pressed again, the pump will run at low speed. If the button is pressed a third time, the jet will shut off.

Temperature Buttons: Control the temperature setting of the water. The temperature setting can be from 80°F to 104°F. The water heats at about 6°F per hour with the cover on. Use a medical or other accurate thermometer to check the temperature of the water. Note: The word “COOL” will appear in the console display if the temperature of the water is more than 20°F cooler than the set temperature. When this hap- pens, the heater will automatically activate to warm the water. The word “ICE” will appear in the display if the temperature drops below 40°F. If this happens, the pump will automatically circulate the water and warm the plumbing to keep the water from freezing.

On/Off Valve: Controls water flow to the two neck jets (see J on page 11).